EN
Connection
30
Directions for use for LED strips
6
Connection
DANGER
Risk of fire due to the overheating of the cable!
Fires resulting from overheated cables can lead to deadly burn injuries or poisoning by
smoke inhalation.
Do not lay the cable when it is unwound.
Use a sufficient cable cross-section.
Take the maximum permissible length of the supply lines into consideration.
Observe the maximum permissible capacity of the power packs and receivers.
ATTENTION!
Malfunction due to damaged cable.
Conducting the cables along sharp edges can lead to malfunctions.
Lay the cables in empty tubes or cable channels.
Deburr the boreholes and notches in LIPROTEC profiles.
ATTENTION!
Malfunction due to the loosening of the cable connection.
Connecting tensioned cables can lead to a loosening of the cable connection.
Guarantee sufficient tension relief.
6.1
Optimizing radio noise suppression
To obtain good radio noise suppression and the greatest possible operating safety, observe
the following points for expert line laying:
Mount the power packs at least 30 cm from the LED-conducting aluminium profiles. In
the process, observe the minimum distances to the neighbouring components (see the
"Directions for use for the power pack," Fig. C).
Properly lay the output lines at a corresponding distance to the earthed metal surfaces.
This reduces capacitive interference.
Make sure the distance between the mains cable and connection cable of the receiver
or LED strip is as large as possible (at least 5 cm) and mains and connection cables are
not laid in parallel.
As a result, interference between the mains cable and lamp connection cables is
prevented.
Avoid intersecting the mains cable and LED modules. If you cannot prevent an
intersection, design it with the largest possible angle as far as possible for technical and
safety reasons.
This prevent HF interference with the mains cable.
Summary of Contents for LIPROTEC LT ES 1
Page 2: ...A E D C B 2 1 2 3 4 r 20mm 1 24V R 230V ...
Page 3: ...F G J H I 24V 230V 24V W R B R G R W 3 2 4 1 9 mm ...
Page 5: ...DE 2 Gebrauchsanleitung LED Streifen 13 Entsorgen 18 14 Gewährleistungsbedingungen 18 ...
Page 23: ...EN 20 Directions for use for LED strips 13 Disposal 35 14 Warranty conditions 35 ...
Page 40: ...FR Notice d utilisation ruban de LED 37 13 Élimination 53 14 Conditions de garantie 53 ...
Page 58: ...NL Gebruikershandleiding LED strip 55 13 Afdanken 71 14 Garantievoorwaarden 72 ...
Page 77: ...PL 74 Instrukcja użytkowania taśm LED 13 Utylizacja 90 14 Warunki gwarancji 90 ...
Page 95: ...TR 92 LED şeritleri kullanım kılavuzu 13 Tasfiye 107 14 Garanti koşulları 107 ...
Page 112: ...PT Instruções de utilização fitas de LED 109 13 Eliminação 124 14 Condições da garantia 125 ...
Page 148: ...ES Manual de uso de las tiras de LED 145 13 Eliminación 161 14 Condiciones de garantía 161 ...
Page 166: ...CS Návod k použití LED pásků 163 13 Likvidace 178 14 Záruční podmínky 178 ...
Page 183: ...HU 180 LED szalag használati útmutató 13 Hulladékkezelés 195 14 Szavatossági feltételek 196 ...
Page 201: ...DA 198 Brugsanvisning LED strips 13 Bortskaffelse 213 14 Garantibetingelser 213 ...