4. Product specifications
32 | 268
Original Operating Manual | Edition 1.0 (01-2020) | CrimpCenter 64 SP
4.3
PLANNING DATA
4.3.1
Installation Location
DANGER
Danger of fire due to electrical voltage!
There is a risk of fire caused by electric arc, electric shock and flying
sparks!
The following instructions are to be followed!
The operating company has to ensure that the machine is connec-
ted according to the electrical connection data.
NOTICE
Damage to property caused by environmental influences!
Avoid the following environmental influences
high humidity.
temperature fluctuations.
aggressive ambient air (saline, corrosive, ...).
These environmental influences can cause damage to the machine and
its components!
Particularly in countries with high humidity condensation can form
on the machine even with slight temperature fluctuations.
The following instructions are to be followed!
Ensure a uniform ambient temperature with constant humidity,
even outside the operating hours.
Be sure to observe the maintenance leaflet for surface care (in the
manual of the base machine).
Damage to the surface coating must be repaired immediately.
NOTICE
Danger of over heating!
Over heating may occur if the fan exhaust is blocked in any way.
The following instructions are to be followed!
Do not block or cover the ventilator exhaust for the cooling air.
The
CrimpCenter 64 SP
is installed and operated as a stand-alone machine.
The maximum load of the ground must not be exceeded and it must be even.
Install the
CrimpCenter 64 SP
in a horizontal and stress-free position using the installation
devices. Height from floor to the upper side of the aluminum base plate must be 940 + 5
mm (37" + 0.2"). The height adjustable hinged feet must be secured by tightening the
counter nuts.
All power supply and control cables are to be properly installed and connected.
The operating company is responsible for the correct power supply. For a safe operation
the machine has to be connected according to the electrical connection data.