9. Servicing / Maintenance
214 | 268
Original Operating Manual | Edition 1.0 (01-2020) | CrimpCenter 64 SP
9.5.8
Motors
» Standstill Monitoring
Task
Check the standstill monitoring of the motors.
Duration
-
Interval
-
Personnel qualifica-
tion
Qualified Personnel
1.
▹
The operating company has to make sure that the safety devices are checked yearly
according to the following instruction.
➥
The checks must be recorded.
➥
It is recommend taking the checks into the operator instruction.
Should one of the tests be negative, you must follow the following points!
Stop the machine immediately!
Immediately contact the service of Schleuniger!
WARNING
Personnel Qualification and Personal Protective Equipment!
The following instructions are to be followed!
The test and report may only be executed by technical specialists.
See also chapter “Personnel Qualification” and “Personal Protective
Equipment”.
Element
Status / Condition / Position
Main Switch
On
Emergency stop switch (All)
Not pressed
Control voltage
On
Safety Cover
This side up
EASY Software
Started and logged in
Before the test is carried out, it must be changed into the following EASY menu.
Press the following button: