8. Commissioning
126 | 268
Original Operating Manual | Edition 1.0 (01-2020) | CrimpCenter 64 SP
8.4
TOWERLIGHT
The Towerlight displays the status of the CrimpCenter with light and sound (optional) and is
available in different versions.
Version without siren
Version with siren
If the CrimpCenter does not have a siren, you can retrofit it.
Please contact your local
Schleuniger
representative who will gladly help you.
The Towerlight can be individually adjusted. There are two options available.
Standard configuration
Custom configuration
8.4.1
Overview
1
2
3
4
5
Siren Element (1) (Optional)
In the event of any machine standstill error, an audible
signal will sound in addition to the visual signal.
Machine downtime
Error message in EASY software
LED Element - Red (2)
The LED Element - Red lights.
Machine downtime
Error message in EASY software
LED Element - Yellow (3)
The LED Element - Yellow lights.
Standby during set-up
LED Element - Green (4)
The LED Element - Green lights.
Production
LED Element - Yellow (3) and Green (4)
The LED Element - Yellow and Green lights.
EASY "Production" menu is open
EASY "Sample" menu is open
LED Element - Blue (5)
The LED Element - Blue lights.
Service