7. Installation / Mounting
Original Operating Manual | Edition 1.0 (01-2020) | CrimpCenter 64 SP
107 | 268
Demounting
The module is located in the CrimpCenter on a mounting rail and is fastened there with a
screw. The supply lines are connected to the CrimpCenter under the conveyor belt module.
Fig. 41: Conveyor belt - Connections - Con-
trol cabinet
Fig. 42: Conveyor belt - Connections -
Machine Frame
1.
▹
Make sure that the CrimpCenter is
switched off
, the main switch is
Off
and the main
pneumatic valve is
closed
.
2.
▹
Mark all cables of the conveyor belt connected to the CrimpCenter.
3.
▹
Loosen them carefully.
4.
▹
Make sure that the cables are not damaged.
Notice
We recommend to pack the cable ends, to roll them up if necessary and to fix them.
5.
▹
Remove the marked screw and washer.
» Keep the screw(s) and washer(s).
6.
▹
If necessary, provide the suitable holder.
7.
▹
Carefully pull the module out of the
CrimpCenter.
» Put the conveyor belt on the holder.
Installation
The mounting takes place in reverse order.
Notice
Note that the conveyor belt must be aligned.