Schlage WRI400 Instructions Manual Download Page 1

*P516-100*

P516-100

WRI400

Wireless Reader Interface

Instructions for WRI400

+

-

+

-

C

B+

1

+

+

1

1

GND

GND

IF RADIO BOARD PRESENT

NC

BATT

COIN CELL NOT NEEDED

NC

C

NO

C

NO

PRIMARY SIDE

BEEPER

BEEPER

ALARM

STRIKE

AUX

PWR/

SIDE UP

LINE

GND

RT

E

GND

GND

1

1

1

1

RED

GRN

GND

DA

TA\D0

CLK\D1

GND

SWITCH INPUT

CLK\D1

DA

TA\D0

RED

GRN

READER1

READER2

TAMP2

TAMP1

DPS

RT

X

GND

DEBUG

TAMPER

STATUS

RELAY

RX/TX

USB

+12V

+5V

LID

+3.3V

RX

TX
GND

OPEN

A-

1

1

1

1

1

1

1

1

23394075_C

SCHLAGE

LINK

RESET

TAMPER

GND

20

19

2

1

ICLK

IDAT

RB8

RB7

GND

VDD

MCLR

USB

AA

BATT

LINE

ALR_NC

ALR_C

ALR_NO

AUX

AUX

AUX

STR

STR

STR

RB+

TB+

TA

-

RS485

12/24VDC

THIS

MOUNT

LED2

BATTERY_HOLDER1

R1

12 C61

U4

REL1

J3

J7

REL2

REL3

U5

TP25

TP24

TP23

TP22

TP21

J6

LED1

LED4

LED7

LED5

LED6

LED3

J18

J17

J13

LED8 LED9

C32

J9

J12

J11

J10

J8

S3

S2

S1

J5

J2

J1

Para el idioma español, navegue hacia www.allegion.com/us

Pour la portion française, veuillez consulter le site www.allegion.com/us

Summary of Contents for WRI400

Page 1: ...PER STATUS RELAY RX TX USB 12V 5V LID 3 3V RX TX GND OPEN A 1 1 1 1 1 1 1 1 23394075_C SCHLAGE LINK RESET TAMPER GND 20 19 2 1 ICLK IDAT RB8 RB7 GND VDD MCLR USB AA BATT LINE ALR_NC ALR_C ALR_NO AUX A...

Page 2: ...he WRI400 9 Wiring the WRI400 to access control peripherals 10 WRI400 Cable wire specifications 10 Portal inputs 12 Portal outputs 13 Credential readers 15 Power failure modes 16 Handheld device HHD 1...

Page 3: ...uipment manufactured and or sold by Allegion LLC is not rated for or intended for use in life safety installations UL listed panic hardware must be used to allow emergency exit from the protected area...

Page 4: ...e UL listed power sources for the WRI400 and the readers is an acceptable alternative 7 Install the Panel Interface Module PIM400 TD2 or PIM400 485 See the installation guide that came with the PIM or...

Page 5: ...a Module ANT400 with the PIM400 and choose a location that is free of obstacles which may cause a reduction in signal power at the receiver The distance between the PIM400 and its antenna should not e...

Page 6: ...n optional remote antenna L L To avoid damage to electronics inside the enclosure when drilling use light pressure so that the bit does not penetrate very far when it breaks through the enclosure or r...

Page 7: ...e of the building s outer wall nearest the gate Use a remote antenna with the PIM400 and mount the antenna on the outside the building in direct line of sight to the WRI400 s L L If the WRI400 is moun...

Page 8: ...0 Cabled hoist machine installations with lower machine rooms Use a Remote Antenna Module ANT400 with the PIM400 to prevent contamination of the PIM400 from settled dust oil and debris Hydraulic machi...

Page 9: ...the bit does not penetrate very far when it breaks through the enclosure or remove electronics from the enclosure before drilling Mounting the WRI400 Follow these steps to permanently attach the WRI40...

Page 10: ...RI400 enclosure door and generates a tamper trouble signal when the lid is open When terminals J2 1 and J2 2 are shorted a tamper trouble signal is sent to the UL listed access control panel WRI400 Ca...

Page 11: ...DC THIS MOUNT LED2 BATTERY_HOLDER1 R112 C61 U4 REL1 J3 J7 REL2 REL3 U5 TP25 TP24 TP23 TP22 TP21 J6 LED1 LED4 LED7 LED5 LED6 LED3 J18 J17 J13 LED8 LED9 C32 J9 J12 J11 J10 J8 S3 S2 S1 J5 J2 J1 Ground Re...

Page 12: ...tatus signal to the ACP Switch closed GND Request to Enter GND J13 3 Ground Electrical ground common for the WRI400 RTX J13 4 Request to exit When the switch opens or closes the WRI400 will send a Req...

Page 13: ...ption STR_NO J6 1 Strike normally open The strike relay is capable of switching up to a 6 Amp resistive load at 24 VDC 6 Amp at 120 VAC or 3 Amp at 240 VAC STR_C J6 2 Strike common STR_NC J6 3 Strike...

Page 14: ...onduit as any other WRI400 wiring Connect the shield of the portal output cables to the appropriate earth ground terminal of the electrical lock load or auxiliary load power supply The shield SHOULD N...

Page 15: ...J18 1 Credential reader inputs Each input line is pulled to GND through a 12V transient suppressor and a 2 mega ohm resistor Wiegand or magnetic format is automatically detected DATA D0 J17 2 J18 2 G...

Page 16: ...effect For the system to fail secure the secure mechanism must be tied to the normally closed side For fail secure UL listed panic hardware must be used to allow emergency exit from the protected are...

Page 17: ...LED7 LED5 LED6 LED3 J18 J17 J13 LED8 LED9 C32 J9 J12 J11 J10 J8 S3 S2 S1 J5 J2 J1 J5 USB L L The WRI400 is communicating with the HHD when the USB LED blinks green and the HHD display indicates WRI40...

Page 18: ...ed and the WRI400 must be linked to the PIM400 Link the WRI400 to a PIM400 The WRI400 and PIM400 must be linked for programmed credentials to function L L Make sure the PIM400 is in link mode Refer to...

Page 19: ...utton Test will not result in the loss of any WRI400 settings or programming changes 1 While holding the Schlage button press and release the reset button 2 All relays on board LEDs reader LEDs and re...

Page 20: ...red blinks from the RX TX is normal for an unauthorized card The credential reader is not operating properly The WRI400 STRIKE Relay LED is not activated when a card or keypad credential is presented...

Page 21: ...access control panel Aux relay action is assigned by the access control panel A credential must have aux relay rights before the ACP will command the WRI400 to activate the aux relay The aux relay wil...

Page 22: ...valid credential to the reader within 5 secs If the credential is not presented within 5 seconds time out will occur Note WRI400 must be in factory default state to program the master construction cre...

Page 23: ...ency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communication However there is no guarantee that interference will not occur in a...

Page 24: ...Antennas having a gain greater than the antenna type approved in the list are strictly prohibited for use with this device However antennas of the same type with a gain equal to or less may be used Ex...

Reviews: