4.2.2

 

SETTING READER GENERAL PROPERTIES  

 

After configuring Reader Properties, the reader settings must be loaded to the access control panel. 

 

The General Options tab offers a variety of options to control reader events.   

 

Figure 17 – Reader Properties: Configuring the General Options   

 

Disabled or grayed out options are not supported for Schlage readers 

 

System Galaxy Integration to Schlage AD400/AD300 

Page 36 

Summary of Contents for AD-300

Page 1: ...k Guide CONFIGURATION AND OPERATION SCHLAGE AD400 AD300 WIRELESS HARDWIRED READERS and PIMS 635 CPU 635 DSI Boards are Required SG 10 2 0 OR HIGHER UPDATED MAY 2015 System Galaxy Integration to Schlage AD400 AD300 Page 1 ...

Page 2: ...1 845 6600 www galaxysys com No part of this document may be reproduced copied adapted or transmitted in any form or by any means electronic or mechanical for any purpose without the express written consent of Galaxy Control Systems Copyright protection claims include all forms and matters of copyrighted material and information including but not limited to material generated from the software pro...

Page 3: ... 3 SYSTEM GALAXY SOFTWARE REQUIREMENTS 17 1 7 4 SCHLAGE SOFTWARE REQUIREMENTS 18 2 OVERVIEW OF EVENT COMMUNICATION 19 2 1 ON LINE EVENTS EXPLAINED 20 2 1 1 ACCESS DECISIONS AT THE PANEL 20 2 1 2 UNINTERRUPTED EVENT LOGGING 20 2 2 OFF LINE EVENTS EXPLAINED 20 2 3 WHAT EVENTS come from a SCHLAGE READER 21 2 4 NUMBERING SCHEMES FOR PIMS WIRELESS READERS 22 2 4 1 Valid Addressing of an AD400 only Netw...

Page 4: ... Channels in System Galaxy 32 4 2 Configuring the Reader Properties in System Galaxy 34 4 2 1 Setting Reader Properties in System Galaxy 34 4 2 2 Setting Reader General Properties 36 4 2 3 Setting Reader Schedules 37 4 2 4 Setting Reader Alarm Options 38 4 2 5 Setting Reader PASSBACK WHO S IN Options 39 4 2 6 UNSUPPORTED Reader Options 39 5 APPENDIX OF TABLES AND TIPS 41 5 1 READER MAPPING TO DEVI...

Page 5: ...Channel AD300 AD400 MIXED NETWORK 33 Figure 14 Reader Properties Configuring the PIM Number AD300 ONLY HARDWIRED 34 Figure 15 Reader Properties Configuring the PIM Number AD400 ONLY WIRELESS 35 Figure 16 Reader Properties Configuring the PIM Number AD300 400 MIXED NETWORK 35 Figure 17 Reader Properties Configuring the General Options 36 Figure 18 Reader Properties Configuring the Timing Schedules ...

Page 6: ... well as AD300 Readers Schlage Wireless Test Kit AD400 AD300 Readers come in ABA and Wiegand formats you cannot mix card formats on the same network bus i e DSI board section For information about integrating with legacy Schlage PIMs WAPMs see the Galaxy 485 ODT PIM Guide For complete list of requirements see the Requirements section of this guide 1 2 UNSUPPORTED READER OPTIONS The following reade...

Page 7: ...nts and credentials presented at the wireless door are sent thru the PIM to the Galaxy Panel The Galaxy Panel returns the access decision to the PIM logs event with the Comm Server and SysGal database Figure 1 SYSTEM DIAGRAM AD400 PIM Readers on RS 485 Multi drop IMPORTANT The Card PIN high security mode is not supported at this time Each section of the DSI board can support the same card format i...

Page 8: ...k to AD400 PIMs You must set the Network Type to AD400 wireless only on the Serial Channel in SG software 1 4 2 ADDING AD300 S TO AN EXISTING AD400 SYSTEM a DEDICATED NETWORK You can install AD300 hardwired readers onto a separate DSI section In this case you must set the Network Type to AD300 hardwired only the Serial Channel in SG software for the new AD300 network bus Note It is a requirement t...

Page 9: ...Only In the Reader Properties screen the operator must assign the correct PIM number to each reader according to what was programmed into the PIM Why make an AD300 only channel Convenient programming the SG software automatically sets the PIM numbers in the software for every AD300 reader that you add to the software from the Serial Channel screen Eliminate potential conflicts with wireless PIM ad...

Page 10: ...re operating system and guidelines for system architecture as well as 3 rd Party integrations SG v10 Software User Guide Describes how to configure and operate most features of the software 635 series Hardware Guide Describes how to install and configure the hardware and its peripheral devices readers inputs outputs etc SG Integration to Schlage AD400 Describes wiring the AD 400 PIM to the DSI in ...

Page 11: ...sure all daughter boards have finished flashing before attempting to load boards or connect devices ALSO SEE See the Appendix of this guide for tips and or the Galaxy 600 635 Hardware Guide for detailed flashing instructions 1 7 1 2 Maximum CPU Device Load A Galaxy 635 series controller can support up to 64 devices per CPU board The device count by board type is listed below DPI Board 2 i e suppor...

Page 12: ...Network is when a DSI 485 Channel that has both AD300 Hard wired Readers installed along with AD400 wireless readers Ensure correct addressing of readers PIMs and setting of HI LO reader ranges See section on addressing readers for mixed networks Dedicated Network when a 485 Channel is dedicated to communicating with only one model of reader Thus the wireless and wired readers are installed on sep...

Page 13: ...ges of one PIM with other PIMs The HI Number defines the highest reader number that can link to the PIM The LO Number defines the lowest reader number that can link to the PIM When numbering and linking readers you can skip or omit using a reader number but you can t link readers that are outside of the HI LO Range e Each AD300 Reader must have a unique number on the 485 channel 1 16 is valid zero...

Page 14: ... may be to your liking d You must set the appropriate Network Type in the Serial Channel Programming screen in the System Galaxy software to match the installation i e Mixed Network or dedicated network for AD400 ONLY and AD300 ONLY 1 7 1 6 Reader Formats for AD Series Wiegand and ABA Readers cannot be mixed on the same 485 channel see System Concept Diagram Put ABA readers on a separate 485 chann...

Page 15: ...the legacy model PIMs or visa versa 2 You must still meet requirements for unique PIM Reader addressing and HI LO ranges of the PIMs on the network Newly added PIMs must meet wiring distance requirements Newly added PIMs must use a unique address on the 485 channel not already taken by an existing PIM Newly added PIMs must declare a HI LO Range that does not overlap an existing PIM s HI LO Range N...

Page 16: ...hannel with legacy ODT PIMs Readers but you cannot link new AD400 readers with the old ODT PIMs You must match wireless reader models the PIM it was designed to work with All the same rules apply for unique addressing and HI LO range whether they coexist on the same 485 network or on separate channels See diagram examples in the installation instructions of this guide 6 Credential types supported ...

Page 17: ... GENERAL OPTIONS that are NOT Supported Disable Request to Exit Message Enabling Duress Two Person Rule Energize Relay 1 on Pre Arm delay Elevator Reader Lock when Door Closes this is controlled by the wireless reader b TIMING SCHEDULE OPTIONS that are NOT Supported PIN Required Schedule Require Valid Card before auto unlock AKA snow day rule PIN Mode High Security Unlock Delay time Unlock Duratio...

Page 18: ... work with the first Hand Held Device 2 The Windows Mobile Synchronization software must be installed on your PC this is used to transfer Schlage firmware and software files from your PC the Schlage HHD and PIM Schlage devices If Mobile Synchronization software is not on your PC go to www microsoft com windowsmobile en us downloads and download the Mobile Device software that matches your Windows ...

Page 19: ...t to the Galaxy 635 series Panel using the RS 485 two wire protocol 3 The Galaxy 635 series Panel logs the event and returns an access decision valid or invalid back to the PIM provided the card has been enrolled given permission to the Loop Door for the time period the card was used and has been in and loaded to the Galaxy access control panel 4 The PIM receives transmits the access decision to t...

Page 20: ... between the panels and the SG Database The core GCS services continue operation as long as the PC is powered on Therefore events that occur while the SG software is logged out shut down or while the user is logged out of the PC OS will be available from System Reports based on the logging to the database 2 2 OFF LINE EVENTS EXPLAINED Offline events means the Galaxy panel is unable to communicate ...

Page 21: ...so generated if the door is forced open without using a key or credential REQUEST to EXIT REX is generated by moving the inside door handle lever NOTICE The outside door lever is always movable and always generates an REN event regardless of the door status door schedule or access rules authorized denied of the credential However the door cylinder should only retract open when a valid access condi...

Page 22: ... are valid on the network bus no duplicate PIM numbers allowed You must configure the HI LO RANGE in the PIMs you cannot link a reader to a PIM who s Reader ID is outside the HI LO Range Do not overlap HI LO RANGES 2 4 1 VALID ADDRESSING OF AN AD400 ONLY NETWORK You must use unique numbers for the PIM ID and Readers The diagram below shows an example of valid device numbering for Schlage AD 400 PI...

Page 23: ...AD400 PIM address AD300 Readers must be given a binary address that is outside of the HI LO Range of any AD400 PIM on that same network bus Notice that Readers 5 and 6 are AD300 s and they are not within the two AD400 PIM ranges of 1 2 and 3 4 Each AD400 Reader must be given a binary addressed that is within the HI LO Range of the PIM it is linked to and the address must be unique not duplicated b...

Page 24: ...ting Wireless Reader ID s Example A It is INVALID duplicate or overlap numbers in the 485 multi drop Example B Figure 5 Example A SKIP OMIT A NUMBER is OK VALID Figure 6 Example B DUPLICATE or OVERLAPPING NUMBERS ARE INVALID CAUTION If you need to correct a duplicate overlapped or incorrectly numbered a reader you may need to re link some or all the readers on the network System Galaxy Integration...

Page 25: ...he serial programming cable to configure the correct network parameters into the CPU and configure the board ID on the DSI o If you are using a 635 CPU you can configure it using the 635 Web configuration Tool see the Web Config Tool Guide The main 635 Hardware Installation manual provides requirements and hardware installation instructions for the 635 series hardware CPU and its daughter boards T...

Page 26: ...r wires on the Galaxy DSI ports T to R and T to R You must also install the two black jumpers on every PIM unit see diagram below Landing the wires from DSI T to PIM R and DSI T to PIM T use diagram below You must ground the shielding on for every segment of RS 485 cable on one end The following diagram shows shielding grounded on the controller end The PIM unit should be powered on a separate pow...

Page 27: ...s 2000 download Microsoft ActiveSync For Windows Vista download Microsoft Windows Mobile Device Center c Launch the installer and follow the on screen instructions 2 Go to the Schlage support website www schlage com support Download from the VIEW link on the table the v 2 17 package version for the AD 400 firmware NOTE the AD 400 is firmware version is actually 2 15 3 Download the SUS v4 4 0 setup...

Page 28: ...85 etc load card data access rules schedules holidays reader properties etc monitor doors events send door commands etc System Tray Icons if you are on XP GCS Client Gateway Service systray icon looks like a PC monitor GCS Communication Service systray icon looks like a yellow control panel GCS DBWriter Service systray icon looks like a database symbol GCS Event Service systray icon looks like a g...

Page 29: ...You must configure all options according to the agreement The Max Readers count the Max DSI Based Readers count must match the purchase agreement b UPGRADING REGISTRATION ADDING WIFI READERS you must update the Max Readers count this is the total number of readers in the system including the total number of wireless readers the Max DSI Based Readers count this is the total number of wireless reade...

Page 30: ...t Loop Type to 600 Set Connection Type to TCP IP Enter the IP address of the Event Server the PC running the GCS Event Service Remote Port should be 4003 Enter the computer name of the Communication Server the PC running the GCS Communication Service you can click the This Computer button if you are programming this on the communication server Click Apply to save settings Figure 9 Loop Cluster Pro...

Page 31: ...y descriptive Name for the control panel The software automatically assigns a controller name you can should change that to a name that logically describes the location or purpose of the panel i e Lobby controller or East Wing 1st floor etc for administration and future maintenance purposes 4 Click the Get Board Info button the Board Info screen will open and display the list of boards in that pan...

Page 32: ...Channel from the SG menu 1 Select the Cluster Loop Name 2 Select the Controller Name 3 Select the appropriate DSI Board section number e g Board 1 Sect 1 from droplist 4 Click Edit button 5 Set the Channel Mode Wiegand or ABA NOTE setting a channel to Unused will disable the channel 6 Select the correct Network Type 7 check the appropriate reader numbers ID s that you have attached to this DSI cha...

Page 33: ...Figure 12 Serial Channel AD400 ONLY WIRELESS NETWORK Figure 13 Serial Channel AD300 AD400 MIXED NETWORK System Galaxy Integration to Schlage AD400 AD300 Page 33 ...

Page 34: ...ur DSI 485 Channel Select the specific Reader Name you are setting up then click the Edit button You can change the Reader Name up to 65 characters to something that describes the reader i e Room 101 supply closet The system mapping for that board is still displayed above the reader name field The Reader Type field will be disabled but it will display the format you assigned to this reader in the ...

Page 35: ...K OF THIS GUIDE TO ASSIST YOU WITH RECORDING YOUR ACTUAL PROGRAMMING SO YOU KNOW WHICH PIM TO CHOOSE Figure 16 Reader Properties Configuring the PIM Number AD300 400 MIXED NETWORK In this screen shot notice that the PIM Number must be configured by the installer For an AD400 Reader the PIM number must match the PIM number that this reader is linked to For an AD300 Reader the PIM number must match ...

Page 36: ... be loaded to the access control panel The General Options tab offers a variety of options to control reader events Figure 17 Reader Properties Configuring the General Options Disabled or grayed out options are not supported for Schlage readers System Galaxy Integration to Schlage AD400 AD300 Page 36 ...

Page 37: ...e e g 8am to 5pm During the unlocked portion of the schedule the door is open and no card access is required During the locked portion of the schedule an access card must have valid access privileges in order to open the door PIN required schedule not available for Schlage Wireless readers in SG 9 10 Disable Forced schedule when selected the system will not report a door forced condition at the do...

Page 38: ...ated whenever the condition occurs on the reader I O groups are used to activate outputs associated with the alarm condition I O Offsets This field contains the I O Offsets for each condition Acknowledge Select check this checkbox if the condition should appear as an alarm event in alarm events window Priority The Acknowledge check box must be selected before Priority will apply The priority field...

Page 39: ...options are not supported for Schlage readers 4 2 6 UNSUPPORTED READER OPTIONS The following reader options are not supported with Schlage wireless readers Relay 2 configuration is unsupported You cannot use a Schlage reader for an elevator reader when wired through a DSI board Door Group and Door Interlock features are unsupported Duress is not supported Pin Schedule Mode is not supported High se...

Page 40: ...System Galaxy Integration to Schlage AD400 AD300 Page 40 ...

Page 41: ...DWARE SG SOFTWARE LOOP UNIT BOARD ID SECTION HUB ADDRESS No of Locks paired to HUB Enabling of DSI Readers Mapping of reader numbers LOOP 1 UNIT 1 DSI 5 1 1 2 Select Loop 1 and controller 1 board 5 sect 1 Choose the correct Schlage type and network type and enable check readers 1 and 2 reader assigned to Board 5 Sect 1 1 maps to PIM 1 READER 1 Board 5 Sect 1 2 maps to PIM 1 READER 2 LOOP 1 UNIT 1 ...

Page 42: ...HARDWARE APERIO HARDWARE SG SOFTWARE LOOP UNIT BOARD ID SECTION HUB ADDRESS No of Locks paired to HUB Enabling of DSI Readers Mapping of reader numbers System Galaxy Integration to Schlage AD400 AD300 Page 42 ...

Reviews: