10 Technical data failsafe brake
Operating Manual Linear ACTUSAFE CMFS(L)
OM-ENGLISH-Failsafe-Linear-16xx-V2.00-2022.03.03
10
Technical data failsafe brake
10.1
CM03FS(L)
Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 W
Voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 V
Current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,67 A
10.2
CM06FS(L)
Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 W
Voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 V
Current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,875 A
10.3
CM12FS(L)
Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 W
Voltage: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 V
Current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,17 A
11
Spare parts
When ordering spare parts, let us know the serial number of the actuator.
A separate exploded diagram and a spare parts list is available for selecting spare parts.
12
Lubricant recommendation / Lubricant requirements
See Operating Manual ACTUSMART CM.V1.2, section 15, page 76
12.1
Lubricant points FS(L)
The table values given apply to relubrication in accordance with the relubrication intervals in the operating instructions.
After relubrication has been carried out, 2-3 full strokes must be performed. If torque switch off occur, the grease nipples
must be removed and the strokes repeated.
NOTE:
Lubricant can leak out of the lubrication points.
After that the grease fittings should be installed .
At initial assembly or upon complete disassembly of the spindle nut is filled, all gears and bearings pocketed filling. All
moving parts as well as internal surfaces are coated to cover them.
→
Lubricant quantity according to expenditure
→
Lubricant specification according to the operating instructions depending on the temperature range
Type
Lubrication point
[
Quantity
]
1
2
Bearing
Intermediate gear
[
cm
3
]
[
cm
3
]
CM03FS(L)30_5
4
-
CM03FS(L)50_8
5
-
CM03FS(L)100_12
8
-
CM06FS(L)100_30
12
35
CM06FS(L)170_25
15
35
20