background image

FORCED AIR OIL CONSTRUCTION HEATERS

INSTRUCTIONS AND PARTS LIST

MODELS

      50,000 BTU/HR

   100,000 BTU/HR

150,000 BTU/HR

            K50-FA

 K100-FA

K150-FA

          SPC-K50

         SPC-K100

SPC-K150

YOUR SAFETY IS IMPORTANT TO YOU  AND TO OTHERS,
SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU
OPERATE THIS HEATER.

!

GENERAL HAZARD WARNING:

FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH
THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY
LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION,
CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.

ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD
USE OR SERVICE THIS HEATER.

IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS
MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.

!

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

September 2000

8124B

ANSI Z83.7b-1993

Construction Heater

Summary of Contents for 50,000 BTU/HR K50-FA SPC-K50

Page 1: ...AUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRICAL SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC...

Page 2: ...e operated in the presence of other people the user is responsible for properly acquainting those present with the safety precau tions and instructions and of the hazards involved SAFETY PRECAUTIONS 1 Check the heater thoroughly for damage Never operate a damaged heater 2 Never modify the heater or operate the heater if it has been modified from its original condition 3 Use only Kerosene or 1 fuel...

Page 3: ...when the temperature drops below zero degrees fahrenheit 18o Celsius In extremely cold weather condensation may develop in the tank and it is recom mended that a tablespoon of de icer be added for each gallon 4 liters of fuel in the tank When filling the heater use at least 2 gallons 8 liters of fuel Be sure heater is level and do not overfill Use a funnel or can with a long fill spout WARNING To ...

Page 4: ...ly around the burner and combustion area 3 CAD CELL Clean the glass portion of the cad cell with a soft dry cloth 4 NOZZLE Accumulation of dirt from fuel and carbon from the compressor vanes will eventually fill up the passages in the nozzle resulting in reduction of fuel and air flow Pressure will gradually increase giving improper fuel air mixture and excess odor and smoke If this occurs replace...

Page 5: ...a 1 16 gap 063 or single post electrode Solid State Control 25 second Timing 1 ft 38 x 16 x 25 76 lbs 81 lbs 100 100 000 Kerosene or 1 Fuel Oil Only 77 4 1 4 12 115V 60Hz 10 5 5a 100V 3450 rpm 275cfm Direct Spark continuous Transformer 5 000V sec 20ma or ignitor 7000V 1 0 ma 1 16 gap 063 or single post electrode Solid State Control 25 second Timing 1 ft 34 x 16 x 25 69 lbs 74 lbs 50 50 000 Kerosen...

Page 6: ...Page 7 K Heaters ...

Page 7: ... O Ring 33 6849 6849 6849 Nylon Pipe Plug 34 6850 6850 6850 Relief Ball 1 4 Dia 35 6851 6851 6851 Spring 24 O D x 58 36 6856 6856 6856 Hose Barb Fitting 37 6863 6863 6863 Oil Flame Cntrl Assy 38 6865 6865 6865 Cad Cell Flame Snsr 39 1775 1719 Comb Cmbr Cyl Assy 40 3843 3843 3843 Electrode Mtg Brkt 41 6993 6993 6993 Oil Fuel Cap 42 3423 3423 Start Relay Brkt 43 7399 6841 6841 Motor 1 4 HP 44 7417 7...

Page 8: ...SCHEUPRODUCTSCOMPANY INCORPORATED Mail P O Box 250 Upland CA 91785 Plant 8855 Baker Ave Rancho Cucamonga CA 91730 Telephone 909 981 5343 ...