background image

E

Schaudt GmbH, Elektrotechnik und Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Tel. +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt--gmbh.de

8310068 BA / EN

Date: 19.07.2018

Operating Instructions

Operator and control panel LT 100

Table of contents

1

Introduction

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

Application and function

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Operation

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.1

Layout

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.2

Starting up

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.3

Switching on

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.4

Checking battery voltage

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.5

Checking tank levels

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.6

Troubleshooting and remedies

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.7

Switching off

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.8

Closing down the system

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Maintenance

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Appendix

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of Contents for LT 100

Page 1: ...9 07 2018 Operating Instructions Operator and control panel LT 100 Table of contents 1 Introduction 2 2 Application and function 2 3 Operation 3 3 1 Layout 3 3 2 Starting up 4 3 3 Switching on 4 3 4 Checking battery voltage 4 3 5 Checking tank levels 6 3 6 Troubleshooting and remedies 6 3 7 Switching off 7 3 8 Closing down the system 8 4 Maintenance 8 Appendix 9 ...

Page 2: ...lace high up near the door of the vehicle LT 100 control panel Power supply CSV EBL starter battery car or base vehicle Lighting Pump Heater etc 230V AC 12V consumers Leisure area battery Water tank Waste water tank Fig 1 On board power supply system The main layout of the on board vehicle electrical system is shown in Fig 1 The functions of the LT 100 control panel is to switch on and off the 12V...

Page 3: ...f the 12V supply of the vehicle 2 2 Indicator LED green Indicates the system is switched on 1 2 Check of leisure area battery voltage 2 3 4 LEDs red yellow green green Display of the battery voltage in four incre ments with voltage information and total di scharge warning 1 3 Check of water tank level 2 4 4 LEDs blue Display of water and waste water tank levels 1 4 Check of waste water tank level ...

Page 4: ...st too low battery alarm see chap 3 6 1 3 4 Checking the battery voltage Touch the sensor for the Check leisure area battery voltage F Red LED lights up Battery voltage above 11 0V F Yellow and red LEDs light up Battery voltage above 12 2V F Red yellow und the lower green LEDs ligt up Battery voltage above 12 7V F All LEDs light up Battery voltage above 13 5V The following table shows the correct ...

Page 5: ...upply F Prior to taking the vehicle out of service ensure that no inactive con sumers are still connected Measuring the off load voltage is a simple and effective method of checking the condition of the battery Off load voltage is the voltage of the charged battery in a passive state with no current being supplied or drawn Take the measurement several hours after the last charging In the mean time...

Page 6: ... 6 1 Alarms Y ATTENTION Total discharge results in damage to the leisure area battery F A low battery charge indicated by low voltage must be prevented F Check the voltage regularly see Section 3 4 Y It is best to carry out checks in the morning before 12V consumers are switched on Alarm Possible cause Remedy Totally discharge of the lei sure area battery Voltage of the leisure bat tery has fallen...

Page 7: ...n switch must be switched on g p Leisure area battery not charged Charge the leisure area battery Fuse blown Refer to the operating manual for the EBL CSV power supply Leisure area battery is flat Leisure area battery is discharged Immediately charge the leisure area battery The leisure area battery is damaged beyond repair if left totally discharged for a lengthy period The battery can be dischar...

Page 8: ...cut off switch of the relevant power supply or Disconnect the battery terminals depending on power supply Y Also refer to the operating manual for the relevant power supply EBL CSV 4 Maintenance The LT 100 control panel requires no maintenance Clean the device with a soft slightly damp cloth and mild detergent Never use spirit thinners or similar substances Do not allow fluid to penetrate into the...

Page 9: ...no 43645 0500 MicroFit ST1 e g Molex 3 0 no 43025 0600 12V OFF 12V ON 12V indicator Waste water tank Water tank Mains Sensor LAB Sensor LAB Fig 3 Wiring diagram for LT 100 control panel B EC Declaration of Conformity Schaudt GmbH hereby confirms that the design of the LT 100 control panel complies with relevant regulations The original EC declaration of conformity is available for reference at any...

Page 10: ... report In the event of damage please fill in the fault report and send it with the faulty device to the manufacturer Device type _______________________ Item no _______________________ Caravan Manufacturer _______________________ Model _______________________ Own installation Yes No Upgrade Yes No There is the following defect please select Battery not being charged during power operation Battery...

Reviews: