Date: 30.09.2009

E

Schaudt GmbH, Elektrotechnik und Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Tel. +49 7544 9577-0, Fax +49 7544 9577-29, www.schaudt--gmbh.de

811.573 BA / EN

Instruction Manual

R

Electrobloc EBL 226 C +OVP

Table of contents

1

Safety Information

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.1

Meaning of safety symbols

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.2

General safety information

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

Introduction

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Operation

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.1

Switching System on/off

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.2

Changing the Battery

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.3

System Faults

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.4

Closing down the System

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Application and Functions in Detail

8

. . . . . . . . . . . . . . . . . . . . . . . .

4.1

Battery Functions

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.2

Additional Functions

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Maintenance

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Appendix

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of Contents for EBL 226 C +OVP

Page 1: ... R Electrobloc EBL 226 C OVP Table of contents 1 Safety Information 2 1 1 Meaning of safety symbols 2 1 2 General safety information 2 2 Introduction 3 3 Operation 3 3 1 Switching System on off 3 3 2 Changing the Battery 4 3 3 System Faults 5 3 4 Closing down the System 7 4 Application and Functions in Detail 8 4 1 Battery Functions 9 4 2 Additional Functions 10 5 Maintenance 10 Appendix 11 ...

Page 2: ...ich may have an adverse effect on personal safety or device safety must be rectified immediately by qualified personnel Y DANGER 230 V mains voltage carrying parts Danger of death due to electric shock or fire F Do not carry out maintenance or repair work on the device F If cables or the device housing are damaged no longer use the device and isolate from the power supply F Ensure that no liquids ...

Page 3: ... electronic block Connected devices may be damaged Therefore prior to initial start up F Ensure the living area battery is connected F Ensure that the battery selector switch Fig 1 Pos 1 is set to the correct position for the inserted battery F Make sure the AES fuse Fig 4 Pos 2 is only used when the AES refrigerator is connected Otherwise the living area battery may be to tally discharged Damage ...

Page 4: ...ery or devices connected to the electronic block F Batteries should only be changed by qualified personnel F Follow the instructions of the battery manufacturer F Only connect the electronic block to 12 V power supplies with rechar geable 6 cell lead gel or lead acid batteries Do not use any uninten ded battery types Y Only batteries of the same type and capacity as those installed by the manufact...

Page 5: ... battery Set battery selector switch to Lead gel Insert solar cell connector on the solar charge regulator Start up the system as described in section 3 1 3 3 System Faults A fault in the power supply system is usually caused by a blown fuse The following is protected with a self resetting fuse F Exit step If a fault has occurred here the step switch must not be pressed for about one minute This f...

Page 6: ...e constantly above 14 3 V Defective alternator Check the alternator The refrigerator does not work during mobile ti No power supply to the refrigerator Check fuse and wiring g operation Defective electronic block Contact the customer service department Defective refrigerator Check the refrigerator Solar charger does not work power supply and engine are off Solar panel in partial shade or covered s...

Page 7: ... per month Disconnect the living area battery from the 12 V power supply if you are not going to use the motorhome for a longer period during the winter for exam ple For this the system has a battery cut off mechanism that isolates the living area battery from the vehicle The battery cut off is enabled on the DT LT control and switch panel see operating manual of DT LT control and switch panel Swi...

Page 8: ...is fitted in the electronic block between the mains connection and the charge module R EBL 226 C OVP DT LT Control and display panel Electrobloc 230 V AC 12V consumers Living area battery Starter battery Lighting Pump Heater etc LR Solar regulator accessory LAS Additional charger accessory Side marking lights Fig 2 On board power supply system The EBL 226 C OVP Electroblock contains F Overvoltage ...

Page 9: ...the alternator an auxiliary charging unit or the solar charge regulator even when the battery cut off switch is switched off The switching option provided by the battery selector switch ensures opti mum charging of the two battery types lead gel and lead acid The battery monitor of the DT LT control and switch panel constantly mo nitors the living area battery with dynamic voltage threshold Lower ...

Page 10: ...pts the relevant circuit After rectification of the fault the fuse automatically resets after approx 1 minute Maximum permitted charge current 14 A protected with 15 A Depending on the solar charge regulator used either only the living area battery is charged or the living area battery and the starter battery The power supply to the awning light is automatically interrupted as soon as the engine i...

Page 11: ...ings accessories Schaudt DT LT switch panel required for operation Schaudt battery charger LAS with max 14 A charge currency including suitable connection cable MNL Schaudt Solar charge regulator type LR for solar modules with an overall currency of 14 A with 3 pole connection plug and connection cable C Customer service Schaudt GmbH Elektrotechnik Apparatebau Planckstraße 8 D 88677 Markdorf tel 4...

Page 12: ...mittent fault loose contact Other remarks E Technical data 230 V AC 10 47 to 63 Hz sinusoidal protection class I 1 9 A Depending on the control and switch panel approx 5 20 mA plus con sumption of controller electronics of refrigerator Measurement approx 10 minutes after disconnection from the mains F not connected to mains F 12 6 V battery voltage F Battery isolation not enabled F Control and swi...

Page 13: ...ully charge phase depends on the type of battery and can be adjusted at the device U Automatic changeover to trickle charge with constant 13 8V In the trickle charge phase the voltage at the output of the charging module is constant Start of a new charging cycle by switching over to main charge if the battery voltage falls below 13 8 V for more than 5 seconds when loaded Start of charge also for t...

Page 14: ...onnector block refrigerator supply D Battery sensor control lines 9 Connector DT LT control and switch panel 10 Connector block light refrigerator control D TV Side marking lights tank heater 11 Connection block awning light pump heater light 12 Connection block solar regulator supply 13 Connection block refrigerator step 14 Connection block additional charger 15 Connection block refrigerator supp...

Page 15: ...sor LAB Mains indicator MS relay 2 Off MS relay 1 Off MS relay 1 On MS relay 2 On Shunt consumer SB LAB sensor Shunt battery 2A 2A 60A Negative LAB sensor D base D input LAB sensor Module 8 Charging relay B1 20A R AES Int Charger 1 230V AC socket Mains 230V 50Hz 14 3V 18A LAS 1218 5 A9 A30 A7 A2 A1 A16 A6 A17 A5 Switch between lead gel lead acid battery Circuit board KPL EBL 226 A7 A9 S 1218 2 Bat...

Page 16: ...Instruction Manual Electrobloc EBL 226 C OVP 16 Date 30 09 2009 811 573 BA EN blank page ...