Plugging Procedure
Connectors UIC 558 – Installation and Maintenance Instructions
6.1 Plugging
X
Open the hinged lid (3) of the coupling receptacle
(4).
In doing so, observe the opening angle:
-
at least 110 °
-
but not more than 130 °
max. 130 °
min. 110 °
3
4
Fig. 20: Open the hinged lid (3) of the coupling receptacle (4):
Opening angle at least 110 °, at most 130 °
X
Position the plug (5) in such a way that the arrow
(6) on the plug is congruent with the arrow (7) on
the hinged lid of the coupling receptacle (4).
6
7
4
5
Fig. 21: Align arrow (6) on plug congruent with arrow (7) on
the receptacle lid
Then insert the plug in such a way that the guide-
ways (2) in the plug slide without much effort into
the slots (1) of the receptacle (refer to
Fig. 19
).
In doing so, take care
-
that plug and receptacle are aligned axially (a
plug set diagonally by more than 8 ° cannot be
plugged by hand anymore!),
-
that the plug is completely (flush) inserted in
the receptacle.
X
After that close the hinged lid (3) by hand until the
locking mechanism (8) on lid and plug latches.
3
8
Fig. 22: Close the hinged lid (3) by hand until the locking
mechanism (8) on lid and plug latches
6.2 Unplugging
X
Open the hinged lid (3) of the coupling receptacle
(4). In doing so, observe the opening angle:
-
at least 110°
-
but not more than 130°
X
Hold the hinged lid (3) and take off the plug (5)
from receptacle (4). Only pull on the plug, not on
the cable.
X
Close the hinged lid (3) by hand until the locking
mechanism (9) on lid and receptacle shell latches.
3
9
9
4
Fig. 23: Close the hinged lid (3) of the coupling receptacle (4)
by hand until the locking mechanism (9) latches