Plugging Procedure
NOTICE
Inappropriate handling when plugging or disconnecting may damage the connectors. The functional safety of
the connectors is no longer guaranteed when parts are damaged.
X
Make sure that the slots (1) and guideways (2) of receptacle and plug always interlock when plugging
(
Fig. 19
)!
X
Take care that plug and receptacle do not tilt and that they are plugged without force.
X
Make sure before the plugging procedure that plug and receptacle as well as the hinged lid of the recepta-
cle are not contaminated. Remove any existing dirt.
X
Make sure that when not mated,
-
the plug is always inserted into a dummy receptacle,
-
the hinged lid of receptacles is closed according to its intended use.
X
Open the hinged lid of the receptacle by an angle of at least 110° but not more than 130° (refer to
Fig. 20
).
Overstretching of the hinged lid may shorten the operational life span of the torsion spring and may dam-
age the hinge mechanism.
X
Always close the hinged lid by hand, don’t let it slam!