16
2016-08-25 / V1.0
Installation
Connectors UIC 558 – Installation and Maintenance Instructions
X
Tighten the 2 screws (D) until the crimp adapter
loosens from the replacement insert and can be
taken off (
Fig. 16
).
D
D
Fig. 16: Pull off crimp adapter from the replacement insert
X
To remove the pull off tool, release screw (F) and
open the clamp (
Fig. 17
).
F
Fig. 17: Remove pull off tool
5.7 Installing the Dummy Receptacle
Installation
The dummy receptacle is installed in the same way as
the coupling receptacles. The dummy receptacle uses
an unpopulated insert without cable and contacts in-
stead of the assembled socket insert with connector
cable or replacement insert with crimp adapter.
X
Install the dummy receptacle as described under
„5.3 Installing Coupling Receptacles“
.
X
Insert an unpopulated insert instead of the assem-
bled socket insert/replacement insert.
Test
X
Check that all of the installed parts are in the cor-
rect position and function properly.
X
Check the functionality of the receptacle lid.
Commissioning
DANGER
In the case of a contact of the traction
current line with the vehicle, the dum-
my receptacle may be highly energised.
Deadly hazard!
X
Before commissioning the dummy
receptacle, a high voltage test must
be carried out.
X
Before commissioning the dummy receptacle, it
must be tested in accordance with EN 50215.
5.8 Installing Wall-mount Cable Glands
for Cable Plugs with Connector
Cable
The connector cables have to be installed in such a way
that they are free from undue tensile, pressure, flexing
and torsion loads.
We recommend using the UIC KK D2 wall-mount cable
gland for installation on the vehicle body.
Preparing measures
For the installation of wall-mount cable glands, a
mounting hole with 30 mm diameter has to be provid-
ed in the vehicle wall.