Functional test
7.1
On board test
Attention: Before starting the on board test, make sure, the
OMD has been maintained according maintenance schedule
(chapter 6). If used make sure, that all siphons have to be
filled with oil (refer to chapter 2.1.3.)
By using the VN Smoke Test-Box you can easily test the functionality of the
VISATRON® oil mist detector and its connection to the safety system of the engine.
The set can be ordered separately under Part.-No. 151780. It consists of the
following parts:
Smoke Test-Box
151780
Smoke tubes
Hand pump kit
Working instruction
Attention: You will stop or slow down the engine
Figure 48
Adapter assembly with smoke tube and pump
Test procedure step by step:
Step 1
Remove the lock screw.
Step 2
Mount the adapter for the smoke tube.
A
B