4
Operating instructions
4.1
Display
After power-on LED 1 is blinking for 30 seconds. The device will show the following
display.
Figure 30:
Normal display mode
In case of a high oil mist concentration the LED bar goes up and at 70 % opacity
compared to the adjusted alarm level the 'Oil-Mist Alarm' LED switches on. At
100% opacity, compared to the alarm level, the 'Oil-Mist Alarm' LED starts blinking.
If the opacity later goes down, the alarm condition will be stored.
Figure 31:
Example of an oil mist alarm state
The opacity is shown in the right LED bar. If highest LED is switched on, the opacity
has reached / exceeds the Oil Mist Alarm level.