Removal:
-
Disconnect the sensor from the power supply (M8
plug-in connector) and the ground cable
-
Remove the M8x16 INBUS screw from the center
of the sensor and replace it with the M8x30 INBUS
screw
-
Use the M8x30 INBUS screw to press the sensor
off the surface
-
Place the sensor on the sensor protective plate
-
Remove the M8x30 INBUS screw again so that the
sensor sits flat on the sensor protective plate
-
To protect the screw opening, insert the M8x16
INBUS screw again and tighten it
-
For safety reasons, never transport a sensor
without a sensor protective plate!
Typical installation points can be found in DIN ISO 10816-1
/ DIN ISO 10816-6.
Attention!
Do not reuse sensors with faulty seals on
the magnetic mounting plate. Otherwise,
there is a possibility of cuts due to
splintering of magnetic parts.