Installation:
-
Loosen the M8x16 INBUS screw in the center of
the sensor and replace it with the M8x30 INBUS
screw (Illustration 1)
-
Use the M8x30 INBUS screw to press the sensor
off the sensor protective plate (Illustration 2)
-
Place the sensor on a flat and clean magnetic base
(oil and dirt must be removed beforehand if
necessary)
-
Remove the M8x30 INBUS screw again so that the
sensor sits flat on the installation base (protect the
screw with the sensor protective plate for
transportation
purposes
-
-
To protect the screw opening, insert the M8x16
INBUS screw again and tighten it (Illustration 4)
-
Connect the supplied ground cable to the next
ground point, making the distance as short as
possible (Illustration 5)
-
Check that the sensor is correctly mounted
-
Connect the sensor to the power supply (and data
bus) using the M8 plug-in connector (Illustration 6)