8.1.9 Fault Diagnosis and Func-
tional Test
If a problem occurs, the versatile status return func-
tions of the i
DRIVE
®
scan system can be used for scan
system diagnosis, too. These functions allow to read
for instance
• the current operating state
• the operating state at the moment of the most
recently occurred operation interruption and
• an event code, indicating which particular event
caused the scan head to enter a temporary or
permanent error state.
To verify that data transfer capability between the
RTC
®
5 and a scan system is intact,
can transmit an 8-bit value –
separately for each axis– to the scan system. Subse-
quently, a 20-bit value will be returned on the corre-
sponding status channel: If data transfer is error-free,
then the upper 8 bits of the returned 20-bit value will
be identical with the originally sent 8-bit value, and
the next lower 8 bits will be identical with the
complement of the sent 8-bit value.
These 20-bit values will be returned until the
is used to select another return
data type (see
section "Configuring Status Return
).
To facilitate – after a data transfer verification – resto-
ration of the status return behavior in effect prior to
the data transfer verification, the
allows the prior data type to be temporarily stored for
later retrieval.
8.2 Coordinate Transformations
For precise set-up of the scan system relative to the
image field (if the “second scan head control” option
has been enabled,
two
scan heads can be adjusted
relative to a
common
image field), a linear coordinate
transformation can be defined (separately for the
primary and secondary scan head connectors) for all
X and Y output coordinates (x|y) defined by vector or
arc commands:
The (2 x 2) total matrix M is thereby automatically
calculated by the RTC
®
5 as a product of a scaling
matrix M
S
, a rotation matrix M
R
and a general trans-
formation matrix M
T
:
The coefficients of the three matrices (M
S
, M
R
and
M
T
) and the offset values (x
0
|y
0
) can be individually
defined for the primary and secondary scan head
connector.
The offset (x
0
|y
0
) is set via
For 3-axis scan systems,
enables setting of an offset z
0
for
the Z coordinate, too (z
0
has the opposite effect of
applies:
The coefficients of the scaling matrix M
S
are set via
using a scaling factor
k
that is common to both axes:
The coefficients of the rotation matrix M
R
are set via
by specifying a rotation
angle
(mathematical definition: positive angles
produce counterclockwise rotation):
x'
o
y'
o
M
x
o
y
o
x
o
y
o
+
=
M
M
T
M
R
M
S
=
z
'
o
z
z
o
+
=
M
S
k
0
0
k
=
M
R
cos
o
–
o
sin
–
sin
o
–
cos
=