scandia AVEDUR SCGAS10 Owner'S Manual Download Page 1

AVEDUR

OWNERS MANUAL

Scandia Heating (Aust) Pty Ltd

Head Office

306 South Gippsland Highway
Dandenong South VIC 3175
Australia

Warehouse

Lot 1 Melbourne Cresent,
Seymore VIC 3660
Australia

+61 3 5792 2388
www.scandiastoves.com.au

Model Name

Avedur

Model Number

SCGAS10

Summary of Contents for AVEDUR SCGAS10

Page 1: ...ting Aust Pty Ltd Head Office 306 South Gippsland Highway Dandenong South VIC 3175 Australia Warehouse Lot 1 Melbourne Cresent Seymore VIC 3660 Australia 61 3 5792 2388 www scandiastoves com au Model...

Page 2: ...eaters will offer many years of reliable performance This instruction manual has been developed to ensure optimum performance from your Scandia gas space heater It s very important that you thoroughly...

Page 3: ...AND OTHER SURFACES ARE HOT DURING OPERATION AS WELL AS DURING THE COOLING DOWN PERIOD PRECAUTION SHOULD BE TAKEN AND YOUNG CHILDREN MUST BE SUPERVISED AT ALL TIMES NOTE 1 A SLIGHT SMELL MAY BE APPARE...

Page 4: ...NCE WITH AS4553 2008 AND AS3100 MADE IN CHINA NATURAL GAS PROPANE GAS Inlet gas pressure 1 13 kPa 2 75 kPa Outlet gas pressure 0 95 kPa 2 41 kPa Nominal maximum gas consumption 25 5 MJ h 23 0 MJ h Tur...

Page 5: ...ck 3 Remote Control 4 App Control Module Optional accessory 5 Media Driftwood Log Set with Vermiculite 6 Propane Conversion Kit 7 Owners Manual 1 2 3 4 5 6 7 4 YOUR HEATER AT A GLANCE PROPANE CONVERSI...

Page 6: ...443 1235 608 272 1075 952 4 4 5 86 986 20 66 FASCIA 20 1235 992 608 366 5 51 165 149 Gas Connection 1 2 Male Thread Electrical Connection HEATER PRODUCT DIMENSIONS mm...

Page 7: ...and also include materials that are behind non combustible materials If you are not sure of the combustible nature of a material consult your local fire officials Minimum clearance for a combustible s...

Page 8: ...height 1100mm C Rough opening depth 470mm D Rough opening width 1300mm 7 Minimum clearance for a combustible surface A Mantel height from top of the fireplace opening mm 360mm B Side Wall 80mm C Ceil...

Page 9: ...ecified in the below table 8 INSTALLATION GUIDE FLUE INSTALLATION Vertical Vent Flue Installation Rear Vent Flue Installation Horizontal H Vertical V 1 x 90 Elbow 1 x 900mm flue pipe 1 x 90 Elbow 1 x...

Page 10: ...l I Mechanical Air Inlet M Gas Meter P Electricity meter or fuse box Z Fan assisted appliance only ORANGE SHADING INDICATES PROHIBITED AREA FOR FLUE TERMINALS PROHIBITED AREA FOR FLUE TERMINALS 9 INST...

Page 11: ...over 200 MJ h input up to 250 MJ h input 1500mm Appliances over 250 MJ h input 1500mm K From a mechanical air inlet including a spa blower 1500mm N Vertically below an openable window non mechanical...

Page 12: ...stances below Glass Burner 105mm 265mm 120mm Using the glass fill the burner up to 10 15mm deep evenly spread across the tray Use 3 Lava rocks provided and place them according to the distances below...

Page 13: ...placed in the same location as depicted in the image below Vermiculite Burner with Driftwood Default Vermiculite Burner with Pebbles Place the logs and pebbles provided in their designated location A...

Page 14: ...r jumper inside Please refer to the compliance plate product specification table to ensure the correct injector size Please refer to the compliance plate product specification table to ensure the corr...

Page 15: ...enly and relocate to the desired position Please note Some fascia options are heavy and may need additional assistance when handling Avedur fascia is designed to be installed against plain plaster wal...

Page 16: ...on Media Installation Gas type conversion If required Ensure gas inlet and outlet pressure values are set according to the compliance plate Ensure that a gas leakage pressure test is carried out befor...

Page 17: ...nd after the last button pressed Battery low indicator Indicates that battery power is below acceptable level The symbol will flash to indicate that the batteries need replacing The thermostat will re...

Page 18: ...Of The Week Time Manual Mode 1 Press and release button If the thermostat is off pressing and releasing will turn the thermostat on to the most recently selected working mode The manual mode allows s...

Page 19: ...uggested period settings for each day s are 1 With the thermostat off press and hold the P button for 2 seconds or longer to initiate programming The LCD will display PROG Pd and the time at which the...

Page 20: ...ol unit CAUTION The thermostat has already been programmed with a unique code Do not attempt to teach the RF Thermostat ID code unless instructed by the manufacturer 1 With the thermostat off press th...

Page 21: ...Select the ON button to turn on the heater Once the download has complete go to the settings menu and turn on WiFi Swipe right to increase the flame height Swipe left to decrease the flame height Man...

Page 22: ...artment Vacuum and wipe out dust cobwebs debris or pet hair Use caution when cleaning these areas Screw tips that have penetrated the sheet metal are sharp and should be avoided Remove any foreign obj...

Page 23: ...isolated electrical and gas connections STEP 1 STEP 1 Remove the fascia See instructions on page 14 of this manual Remove the fascia See instructions on page 14 of this manual STEP 3 Some adjustments...

Page 24: ...nition module and remove the pilot assembly from the firebox STEP 5 Ensure that any media has been removed from the burner To remove the burner from the firebox remove 6 screws as shown in the image b...

Page 25: ...e fire fails to reignite contact Scandia Heating Outdoor heavy wind conditions The heater is designed to safely shutdown during heavy wind conditions If this occurs please wait until conditions subsid...

Page 26: ...WIRING DIAGRAM 25...

Page 27: ...AVEDUR EXPLODED DIAGRAM 26 1 2 43 29 32 8 6 9 28 3 44 48 7 26 33 31 47 40 51 49 39 18 10 17 12 37 24 34 50 25 22 42 35 38 15 11 5 16 20 19 23 27 36 14 21 52 30 13 45 41 46 4...

Page 28: ...e 1 SPAV021 22 Modulating valve control 1 SPAV022 23 Adaptor fittings 1 2 to 5 8 4 SPAV023 24 Front component access panel 1 SPAV024 25 Component access panel firebox 1 SPAV025 26 Adaptor fittings ass...

Page 29: ...V108 J Log 2 SPAV109 K Log 3 SPAV110 L Log 4 SPAV111 M Log 5 SPAV112 N Log 6 SPAV113 O Vermiculite SPAV114 P Crushed Glass SPAV115 28 A B C D E F G H I J K L M N O P 46 Top air deflector LHS 1 SPAV046...

Page 30: ...ty period after the date of the original purchase such as to make the gas log fire unfit for normal home use and you comply with the requirements below regarding making a claim then subject to the exc...

Page 31: ...South VIC 3175 Australia Warehouse Lot 1 Melbourne Cresent Seymore VIC 3660 Australia Scandia Heating Aust Pty Ltd 61 3 5792 2388 www scandiastoves com au 11 WARRANTY 30 if you are not a retail purcha...

Reviews: