5
SC 303/313 – 050062-101_rev- 05
Control Panel
Note!
The key must be kept pressed for a few seconds before the function gets
activated.
Q
M ACC B CE
ON/OFF
MOTOR
Positional References
Unless stated otherwise, positions and directions such as left, right, upper,
lower, rear, clockwise and counter-clockwise are given with respect to the
machine when viewed from the front.
Modes of Operation
The SC 303/313 has two modes of operation, continuous counting and
batch counting.
Continuous counting
The machine will count the coins and the display will continuously be
updated with the number of coins counted.
Normally, if no coins pass the coin detector for five seconds the rotating
disc stops and automatically reverses slightly before restarting. If no coins
pass during the next 15 seconds the disc will stop automatically. This may
occur because:
• there are either no more coins to count or
• the flow of coins has been blocked.
This function can be by-passed if desired (see
).
Batch counting
The machine will count the coins up to a fixed batch stop quantity and
then stop. There are seven fixed batch stop quantities at 20, 25, 40, 50, 100,
500 and 1 000. In addition to these there is a temporary batch stop
quantity, see
“Setting a Temporary Batch Stop” on page 8
which can be set
anywhere between 5 and 10 999. This is used if the quantity of coins to be
counted does not exist as a fixed batch stop quantity setting.
Key
Function
MOTOR ON/OFF
Starts and stops the machine.
Q
For selecting batch stop or continuous counting.
M
Resets the display and transfers counted coins to the
memory.
ACC
Shows the number of counted coins stored in the
memory.
B
Shows the contents of bag or tube (number of coins
before reset).
CE
Clears the display.