Digital Wrist Blood 

Pressure Monitor 

SC 6400  

 
 

 

 

 
 
 

 
 
 

- Instructions for use - 

 
 

 

Introduction 
Thank  you  for  deciding  for  the  blood 
pressure  monitor  SC  6400  from  SCALA 
Electronic GmbH. To be able to utilise all 
advantages of the blood pressure monitor 
to  the  fullest,  you  should  carefully  read 
these  instructions  before  using  the 
monitor.  Keep  the  instruction  leaflet  in  a 
safe place. 

 

Safety instructions 
The  blood  pressure  monitor  SC  6400 
enables  you  to  monitor  your  blood 
pressure  regularly.  However,  you  should 
never  change  the  treatment  which  your 
doctor has prescribed  

Self-measurement means monitoring, 

it does not imply diagnosis or 

treatment. 

Discuss unusual values with your doctor.  

Do not change the medication 

prescribed by your doctor. 

The heart rate is not a useful indicator of 
the frequency of a cardiac pace maker. 
Patients  with  cardiac  arrhythmia  should 
use the blood pressure monitor only after 
consulting a doctor. 

 

Features of the SC 6400 

 The  blood  pressure  monitor  has  fuzzy  

logic  to  identify  the  pumping  pressure. 
If  the  pumping  pressure  set  in  the 
factory  is  not  sufficient,  the  device 
identifies this and continues pumping.  

 The device has 85 memory locations. 
 The  date  and  time  are  displayed  and 

stored  together  with  every  blood 
pressure value. 

 If  the  battery  icon  is  displayed,  the 

batteries are discharged and the device 
cannot  be  used  until  new  batteries  are 
inserted. 

 WHO-Interpretation  of  blood  pressure 

readings  with  colored  band

 

(See 

description at page 7). 

 

- 2 - 

 The handcuff is suitable for wrists from 

135 to 195 mm circumference. 

 

Preparing the monitor for 
measurement / changing batteries 
Insert  the  two  supplied  batteries  in  the 
battery  compartment  at  the  side  of  the 
blood pressure monitor as shown.  

Use only alkali batteries (LR03)

If  the  batteries  are  depleted,  the  battery 
icon        is displayed in the top left corner 
of  the  LC  display.  The  battery  needs 
urgent  replacement  because  you  cannot 
use the monitor with depleted batteries. 

 

Device description 

 
 
 
 
 
 
 
 

 
 
 

 

 
Setting the clock  
After you have inserted the two batteries, 
you should set the clock.  
To  set  the  clock,  hold  the  TIME  button 
pressed  for  about  5  seconds.  The  year  
blinks  in  the  top  right  corner  of  the 
display.  
Set the year with the 0/I-START button. 

 

 
 
 
 

- 3 - 

 

When  the  correct  year  is  set,  press  the 
TIME  button  again.  Now  the  1  blinks  in 
the  top  right  corner  of  the  LCD.  It  stands 
for the month.  
Set the month with the 0/I-START button. 

 

Another  press  of  the  TIME  button  sets 
another  1  blinking.  It  stands  for  the  first 
day in the month.  
Set the day with the 0/I-START button. 

 

Another  press  of  the  TIME  button  takes 
you to the clock setting – the hours blink. 
As  earlier,  set  the  clock  with  the  0/I-
START button.  

 

Pressing  the  TIME  button  advances  to 
the minutes setting.  
Set  the  minutes  with  the  0/I-START 
button. 

 

A  final  press  of  the  TIME  button 
completes  the  setting  of  the  date  and 
time. 

 

How  to  obtain  correct  measuring 
results 
To obtain correct readings, measure the  
blood  pressure  always 
under 

the 

same 

conditions,  at  rest,  not 
under  the  effect  of 
alcohol, 

not 

during 

meals,  not  after  heavy 
physical 

or 

mental 

stress.  If  possible,  sit 
down  at  a  table  for  the 
measurement. 

 

Please  note: The  blood  pressure monitor 
must  be  at  heart  level  during  the 
measurement,  otherwise  wrong  readings 
are obtained.  

 
 
 

 
 

- 4 - 

 

The measuring method  
Put the cuff around your left wrist making 
sure  that  the  device  rests  on  the  artery 
and the top edge of the device is about 1 
cm  away  from the  wrist  joint  (Please  see 
the enclosed photo).  

 
 

 

 

The cuff should be applied with moderate 

tightness. 

 

Pressing  the  0/I-START  button  starts  the 
automatic measurement. The cuff inflates 
to approx. 190 mmHg pressure.  
The 

automatic 

deflation 

starts 

the 

measurement.  After  about  3  seconds,  a 
heart  icon  starts  blinking  in  the  LC 
display. If a Korotkoff’s sound is detected 
already at that time, it means a  
systolic  pressure  of  more  than  150 
mmHg.  Then  the  monitor  re-inflates  (to 
about  220  mmHg).  At  the  end  of  the 
measurement,  the  result  is  displayed  in 
the LCD and the cuff deflates. 

 

Aborting a measurement 
You  can  stop  the  measurement  at  any 
time  by  pressing  the  0/I-START  button. 
The BP monitor deflates the cuff instantly.     

 

 
 
 
 

 

 

- 5 - 

 