![Scaime eNod4-F BOX Software User Manual Download Page 56](http://html1.mh-extra.com/html/scaime/enod4-f-box/enod4-f-box_software-user-manual_1205998056.webp)
56/90
User manual SCAIME:
NU-Soft-eNod4F-E-0716_235704-C.doc
Name
Modbus
address
CANopen®
Index/sub-
index
Profibus cyclic
IN/OUT
Acyclic DPV1
slot/index
Type Access
3&4 Set points functioning
0x0056 MSB 0x4609 / 0x01
W: 0x0259
byte
Logical input level
0x0094 LSB
0x5100 / 0x00
(M)
Module 2
/
Byte
RO
Logical ouput level
0x0094 MSB
0x5200 / 0x00
(M)
Byte
13.1
Principles
eNod4
device is fitted with 2 logical inputs (4 logical inputs for IO+ version) and 4 logical outputs that are fully
configurable.
13.1.1
Logical inputs
Each input can work individually in positive or negative logic. A holding time (de-bounced time) attached to all inputs
can be configured.
Available functions see hereunder table:
Function
Operating mode
transmitter
Loss in weight feeder
None
●
●
Tare
●
●
Cancel tare
●
●
Zero
●
●
Transmit measurement
(in SCMBus/fast SCMBus, in CANopen TPDO2
sending if input 1, TPDO3 sending if input 2)
●
Continuous measurement transmit
(SCMBus/fast SCMBus only)*
●
Dynamic zero
●
●
Start/Stop refilling**
●
Start/Stop emptying hopper**
●
Start/Stop dosing**
●
Suspend/Resume batch**
●
Emergency stop
●
Reset totalization and dosing error counter
●
Sensor input control
●
●
* command operates on logical level
** these commands operates on front in a bistable functioning mode. For example for the Start/Stop refilling
command, the first front initiates refilling, the second stops it.