Scaime eNod4-D BOX Manual Download Page 1

NU-eNod4D-ETH-E-0418_216710-E.docx 

SCAIME SAS – Technosite Altéa – 294, Rue Georges Charpak – 74100 JUVIGNY - FRANCE 

Tél. : +33 (0)4 50 87 78 64 – www.scaime.com 

 

 
 
 

 

eNod4-D ETHERNET 

Digital Process Transmitter 

 

 
 
 
 
 

 

 
 
 

 

C

ha

ra

ct

er

is

tic

an

fu

nc

tio

ni

ng

 

Summary of Contents for eNod4-D BOX

Page 1: ...TH E 0418_216710 E docx SCAIME SAS Technosite Alt a 294 Rue Georges Charpak 74100 JUVIGNY FRANCE T l 33 0 4 50 87 78 64 www scaime com eNod4 D ETHERNET Digital Process Transmitter Characteristics and...

Page 2: ...isturbances 16 4 2 Power supply connection 17 4 3 Load cell wiring 17 4 4 IO version 17 4 5 Inputs outputs connections 18 4 5 1 Typical connections 19 4 6 JB4 option 19 4 6 1 Specifications 20 4 6 2 E...

Page 3: ...in dosing processes 31 10 5 Analog output IO version 31 11 DOSING BY FILLING OPERATING MODE 33 11 1 Starting conditions 35 11 2 Cycle description 35 11 2 1 Flow rate control optional 35 11 2 2 Automa...

Page 4: ...art cycle 41 12 3 2 Suspend current cycle 41 12 3 3 Stop cycle 41 13 ENODTOUCH INTERFACE HOMME MACHINE OPTION 42 13 1 Online functioning 42 13 1 1 Startup screens 42 13 1 2 Multi eNod screens 43 13 1...

Page 5: ...ments necessary to perform safely any operation on the PRODUCT This symbol means that there is a risk of electrisation that can lead to death or serious injuries instructions are not followed This sym...

Page 6: ...of the equipment must be connected to Earth 1 5 Installation The PRODUCT must be fitted on a support by using the mounting brackets at the rear of the box 1 6 Maintenance The PRDUCT can be cleaned us...

Page 7: ...r with CANopen and ModBus RTU communication Strain gauges load cell conditioner with Profibus DP V1 and ModBus RTU communication Strain gauges load cell conditioner with Modbus TCP and ModBus RTU comm...

Page 8: ...parameter eNodView software is available in English and French version and can be downloaded from our web site http www scaime com or ordered to our sales department on a CD ROM support 2 4 eNodApp M...

Page 9: ...9 SCAIME Manual NU eNod4D ETH E 0418_216710 E docx 3 GENERAL CHARACTERISTICS 3 1 Dimensions...

Page 10: ...10 SCAIME Manual NU eNod4D ETH E 0418_216710 E docx...

Page 11: ...ex Rate 9 600 115 200 bauds Ethernet 2 x RJ45 10 100 Mbits s Logical inputs Number 2 2 with IO version Type opto insulated type 3 Low level voltage current 0 5 VDC 0 1 5 mA High level voltage current...

Page 12: ...n current 30 mA Isolation 1000 V Speed sensor input IO version IN5 HTL 0 2 5 5 30 VDC IN5 TTL 0 0 5 2 4 5 VDC Isolation 1000 V 3 3 Legal for trade Characteristics Unit Accuracy class III or IIII Maxim...

Page 13: ...to be sealed too eNod4 is fitted with a software sealing for metrological parameters and once activated is composed of an event counter and a CRC value of specific and adjustment parameters These val...

Page 14: ...ion power supply 1 VDC JP1 C blage capteur 6 fils 4 fils 6 wire 4 wire loadcell wiring 2 GND A3 connexion capteur load cell connection 1 Exc JP2 R sistance de terminaison connexion AUX AUX connection...

Page 15: ...s IN OUT 1 IN1 4 V 2 IN1 5 GNDA 3 IN2 6 IN4 4 IN2 7 IN3 5 OUTCOM 8 Iout 6 OUT1 9 GNDA 7 OUT2 10 Vout 8 OUT3 SW1 S lecteur Adresse haute hex High Address selector hex Low 9 OUT4 SW2 S lecteur Adresse b...

Page 16: ...data cables Always route high voltage and data cables in separate ducts or in separate bundles Install the measurement cables as close as possible to grounded surfaces e g supporting beans metal rails...

Page 17: ...en ordering eNod4 product The analog output is both current and voltage galvanically isolated at 1000V Voltage output might be set either 0 5V or 0 10V and the current output to 4 20mA 0 24mA 0 20mA o...

Page 18: ...TL logical level or high voltage 30 V maxi level 4 5 Inputs outputs connections An indicator light in front panel is assigned to each Output Inputs connection CN2 V IN5 TTL IN5 HTL V GNDA IN4 IN3 Iout...

Page 19: ...8_216710 E docx 4 5 1 Typical connections Inputs Connection to a detector Inputs Connection to a push button Outputs Possible connections 4 6 JB4 option PNP S IN IN NPN S IN IN IN IN IN IN Load OUT OU...

Page 20: ...ach load cell so that the potentiometer resistance is as low as possible 2 Lay your reference weight at one corner of your weighing system and note the result of the weighing indicator Repeat this ope...

Page 21: ...river with a maximum blade width of 3 mm 1 Press the black button with the screwdriver 2 Stick the wire end into the relevant opening 3 Release the pressure on the screwdriver 4 Pull slightly the cabl...

Page 22: ...le on CD to order from our sales department Note If eNodView software has been correctly installed it is not mandatory to re install the USB drivers when connecting another eNod4 on the same USB port...

Page 23: ...25 kbit s ON ON OFF X 115200 250 kbit s OFF ON OFF X 9600 500 kbit s ON OFF OFF X 9600 1 Mbit s OFF OFF OFF X 9600 125 kbit s 5 4 Communication protocols Model Communication interface Protocols Connec...

Page 24: ...ing of communications DIN version Box version Simultaneous communication Ethernet RS485 AUX USB yes No Ethernet Yes Simultaneous use of Ethernet with USB port can reduce performance of this interface...

Page 25: ...s Off Inactive Fast blinking Initialization Slow blinking Ready for pairing with mobile device Steady On Active and paired The communication through Bluetooth allows using the dedicated mobile app eNo...

Page 26: ...V V at 15kg put sensor maximum capacity 15 000 and sensor sensitivity 1 870 6 3 Scale adjustment coefficient Initial calibration value can be modified with a scale adjustment coefficient This coeffici...

Page 27: ...ate that rejects the mains frequency harmonics according to the place of use 50 or 60Hz 7 2 Bessel low pass filter A low pass digital filter can be applied as an output of the A D converter The filter...

Page 28: ...8 1 Global weighing diagnosis An internal alarm flag reflects the integrity of the whole measurement chain It s used to set logical output active or optional analog output in an error mode in order to...

Page 29: ...on the chosen logic positive or negative the current stored tare value is erased by a rising or a falling edge Zero one or the other or both inputs can be assigned to the zero function A new volatile...

Page 30: ...progress dosing result available fine feed coarse feed high feed emptying reloading out of tolerances flow rate failure dosing failure 10 2 General functions none the output has no function set point...

Page 31: ...ached to an operating mode See corresponding sections for a complete description 10 4 Feeding mode in dosing processes For the filling and dosing by unloading operating modes it is possible to select...

Page 32: ...the highest value to MC Net measurement analog outputs can be assigned to net measurement copy Maximal value is related to Maximum Capacity parameter and works in mono quadrant functioning only The hi...

Page 33: ...od4 D With its four digital outputs it allows the monitoring of all steps of the dosing cycle Fig 6 and 7 shown below represent graphically how a filling cycle is working and what is the influence of...

Page 34: ...final stabilization time 6 emptying holding time 7 end of cycle waiting time Time start cycle coarse feed fine feed cycle in progress emptying dosing result available Measure 1 4 3 2 2 5 6 target weig...

Page 35: ...escription 11 2 1 Flow rate control optional eNod4 D includes a flow rate control system It makes possible to check that the flow rate during the cycle is sufficient The device controls that the flow...

Page 36: ...is compared to 2 limit values in order to check if it is acceptable a high tolerance tolerance or tolerance in excess if the difference target weight dosing result tolerance where target weight dosing...

Page 37: ...TH E 0418_216710 E docx Else the cycle is suspended until a new request of starting the cycle is activated 11 3 3 Stop cycle This edge active input causes the feeding cycle to be stopped inhibiting th...

Page 38: ...own below represent graphically how a dosing by unloading cycle is working and what is the influence of the variables involved Note Except the reloading max and min levels the variables set used for d...

Page 39: ...echanisms optional for reloading management They allow eNod4 D to enter a reloading phase in case of a lack of product in the tank cycle in progress reloading dosing result available start cycle reloa...

Page 40: ...agnostic register The new cycle is aborted At the end of the cycle an error is reported by an output assigned to the dosing failure function and into a read only diagnostic register The new cycle is a...

Page 41: ...out of low tolerance is active the fine feed is restarted 12 2 10 End of cycle waiting time This delay time is triggered after the control of tolerances or after the end of the reloading phase if the...

Page 42: ...for a redirection to a main screen if the communication is established between eNodTouch and eNod4 communication or an error screen if eNodTouch does not manage to connect to the eNod If there is no e...

Page 43: ...ase the eNod number and have an access to the multi eNod screen please follow the procedure Touch the Fn button of the main screen the main menu appears Enter in the eNodTouch menu Go to the Starting...

Page 44: ...function If starting eNod is disconnected or have communication problems the multi eNod screen appears When settings are finished touch the left arrow button to restart eNod Touch According to the num...

Page 45: ...y the main screen of an eNod touch its display area Example for eNod n 1 To return to multi eNod screen touch the channel red button eNod4_1 eNod4_3 eNod4_5 eNod4_2 eNod4_4 eNod4_6 Multi eNod 6 eNod T...

Page 46: ...od4 the button enters in the state eNod disconnected the data display resumes Identify the communication problem in the following list wiring problem 1 4 communication parameters misconfigured on eNod...

Page 47: ...Manual NU eNod4D ETH E 0418_216710 E docx 13 1 3 Main screen 13 1 3 1 Dosing Mode eNod4 D 2nd keyboard Access to result screen Last dosing result Status bar Dosing Status bar Dosing cycle status Dosi...

Page 48: ...main keyboard to the 2nd keyboard touch To enter the dosing quick access menu touch Dosing faults o F Err flow rate failure o OUT Dosing result upper to max tolerance value o OUT Dosing result lower t...

Page 49: ...alue is the value subtracted from the gross measurement to get the net measurement PRESET TARE function NOTE A previous calculated TARE can be restored using this variable CANCEL TARE function NOTE Ca...

Page 50: ...if starting conditions are satisfied F Start feeder cycle and the extraction B Start Belt dosing cycle Invisible if process cycle is ongoing eNod4 D F and B STOP CYCLE Stop the dosing cycle The dosing...

Page 51: ...t screen can be displayed from the main screen with key The Result screen shows information related to the result of checkweighing cycle eNod4 C or Dosing cycle eNod4 D Last result value and statistic...

Page 52: ...make these buttons visible again stop the results recorder This recording feature is specific to eNodTouch and should not be confused with DSD feature embedded in legal for trade certified eNod4 see D...

Page 53: ...formation about parameters consult eNod4 software manuals Setup menu access can be secured by password see 3 5 1 In that case the following screen is displayed After entering a valid password or OLEG...

Page 54: ...h setup Parameter Possible Value Description Language Fr En Change the language of eNodTouch software Keyboard mask Yes No Enable Disable keyboard display on main screen Password Yes No Enable Disable...

Page 55: ...nable Disable the function to start on main screen of a specific eNod 1 eNod Number Number of starting eNod4 If there is only one eNod4 supported this function is necessarily activate 13 1 5 3 Calibra...

Page 56: ...eight unit 4 visible char Weight measurement unit g kg t lb using for calibration Time unit s mn h Time unit using for calibration eNod4 F and B Only s and h can be selected in eNod4 B Weight unit dis...

Page 57: ...al calibration Allows creating relation between the weighing sensor and the physical values Number of loads 1 2 3 Number of calibration loads used during the physical calibration Load 1 2 3 1 1 000 00...

Page 58: ...peat steps 5 and 6 if several points have been defined Remark If you press the operation will stop and the values will not be saved The latest valid calibration values will be restored Zero Calibratio...

Page 59: ...per Zero calibration must have been done before The steps of this single slope adjustment operation are the followings 1 Define the number of points to realize the calibration and the load values for...

Page 60: ...00 Load cell sensitivity in mV V at maximum capacity Span Calibration correction Span cor 0 9 1 100000 Allows to adjust initial calibration Calibration g 0 9 805470 Allows compensating the gravity dif...

Page 61: ...61 SCAIME Manual NU eNod4D ETH E 0418_216710 E docx 13 1 5 4 I O setup settings Available depending on version IO version only...

Page 62: ...e related input None Zero Tare Clear start cycle stop cycle Suspend cycle Dynamic Zero Manual emptying Belt fault Logic Positive Negative defines the edge or level that triggers input function Debounc...

Page 63: ...t state Mode Windows Hysteresis Thresholds functioning principle Comparison Gross Net result Comparison value for thresholds control Weight pulse external totalizer 0 65535 For external totalization p...

Page 64: ...allows modifying timings on outputs with functions Remote control activation time Result within tolerances and Result out of tolerances activation time and delay Parameters Analog output IO version o...

Page 65: ...error mode in order to warn about any defection on the measurement chain defective measurement This variable is set active when at least one of the followings conditions occurs sensor input control r...

Page 66: ...66 SCAIME Manual NU eNod4D ETH E 0418_216710 E docx Parameter Possible Value Description Metrology Parameters...

Page 67: ...following mg g kg t ct g oz possibility to put spaces after unit The stability criterion must be 0 25 d Filter settling time must be less than 1 second in transmitter mode The quotient Maximum capaci...

Page 68: ...ing Checksum Checksum calculated over set of sealed parameters when legal for trade sealing is being activated eNod program version Program version of eNod4 embedded software eNod metrological version...

Page 69: ...n this subnet Swap data Swap data bytes in Modbus TCP registers 16 bits words Name Profinet station name up to 10 chars with Option Use rotary switch in Name else 15 lower case figures dots and dashes...

Page 70: ...25 to 1600 Hz Bessel low pass filter parameters Filter Order 0 2 3 4 For the suppression of periodic vibrations a Bessel low pass digital filter can be applied as an output of the A D converter Minimu...

Page 71: ...factory setting Allows resetting eNod4 or making eNod4 come back to factory settings Channel name Name or rename the channel with a maximum of 4 characters Parameter Possible Value Description Sensor...

Page 72: ...l result max Tolerance parameter which is expressed in 1 10 of user weight unit and has a default value of 30 If the sensor input control result value is greater than or equal to Sensor input control...

Page 73: ...4D ETH E 0418_216710 E docx 13 1 5 6 Functioning Mode eNod4 C D F B According to the eNod4 model the following screen is displayed to select the functioning mode 13 2 Dosing setup menu eNod4 D eNod4 C...

Page 74: ...0 4 50 87 78 64 www scaime com Detailed explanations on Dosing functioning and parameters could be found into eNod4 D manuals The following setup menu allows modifying the parameters related to dosin...

Page 75: ...tying output is disabled if the net value becomes inferior to this level and if the emptying holding time has elapsed Reloading Min Level 0 1 000 000 Output assigned to the reloading function is activ...

Page 76: ...eight Max empty weight 0 No verification Max empty weight Automatic start Yes No Filling cycle starts automatically when the gross weight is between the Min empty weight and Max empty weight Unloading...

Page 77: ...ing time 0 6553 ms During this delay flow rate and level control are disabled to mask the dynamic effects caused by the related feed activation Page 3 3 Emptying Reloading Holding time 0 65535 ms Defi...

Page 78: ...ts But regardless of these limitations the value calculated automatically is limited to FF level Page 2 2 Correction 0 100 If Automatic correction enabled the correction formula is In flight In flight...

Page 79: ...0 65565 Define the acceptable range for dosing results An output assigned to the out of tolerances is set active if the dosing result is not within the range 13 2 7 Dosing Target values Target adjustm...

Page 80: ...ransition threshold relative to the target weight between the Coarse feed and Fine Feed phase FF to CF Level Used in sequences where FF comes before a CF phase Defines the transition threshold relativ...

Page 81: ...TH E 0418_216710 E docx 13 2 8 Configuration of Quick Access menu Allows selecting the dosing data accessible by the touch from the main screen 3 3 3 and 3 3 4 With the example shown above the touch w...