background image

Select

When Select is activated, the pager will only accept calls

addressed to it. When paged an alert tone will be emitted,

the red lamp will blink, and a voice message will follow.

1. Turn the pager on by moving the Slide Switch to the

“N” position.

2. Press and hold the  RESET/M” button (for noise) and

then press the up/down  

” buttons to set the volume

to desired level.

3. After setting the volume, release the  RESET/M” button

to set the pager to Select mode.

4. Press the  RESET/M” button to reset the pager to

Select mode after a call has been received.

Monitor

When  Monitor  is  activated,  the  pager  will  monitor  all

communication (as a   Carrier Squelch Receiver”) on the

selected channel as well as receiving pages.

When paged an alert tone will be emitted, the red lamp

will blink, and a voice message will follow.

1. Perform steps 1-2 under Select.

2. Press and hold the Slide Switch in  N” position until a

short beep is emitted to set the pager to Monitor mode.

Congratulations!

Your pager sets a new standard in Tone & Voice Paging.

It  is  a  highly  reliable  and  very  compact  synthesized

receiver, equipped with a built-in speaker and cellular

type telescoping antenna and is shipped with a  AA” size

NiCd battery and a single unit desktop charger.

All in all it is infused with the quality and attention to detail

which are the hallmarks of SCA.

Battery Installation

Sceptar can be operated with a single  AA” size battery,

which can be either a dry type (Alkaline) or a rechargeable

700 mAh NiCd (Nickel Cadmium) battery.

1. Ensure the Slide Switch is in the  OFF” position.

2. Move the Locking Slide toward the center of the battery

cover,  as  shown  in  illustration.  Then  slide  the  cover

toward the bottom of the pager to remove it. Insert the

negative (-) end of the battery into the pager first, then

press the positive (+) end down. The battery compartment

is marked with negative (-) and positive (+) positions.

3. Replace the battery cover and reset the Locking Slide.

Single Unit Desktop Charger

Use only the specified NiCd battery type. The charger

will charge one battery,  installed in the pager, as well as

a spare battery.  Pages can be received during charging,

so long as the pager is in  Select” or  Monitor” mode.

3. The  RESET/M” button should not be pressed while

receiving a message or alert tone. Should this occur,

press and hold the slide switch inward until a short beep

is emitted to listen to the remainder of the message.

Mute

When Mute is activated, the pager will only accept calls

addressed to it. When paged the red lamp will blink but

no alert tone will be emitted and the voice message will

not be heard.

1. Perform steps 1-3 under Select.

2. Move the Slide Switch to the  M” position.

3. Move the Slide Switch to the  N” position to listen to a

message after the red lamp blinks.

4. Move the Slide Switch back to the  M” position to reset

the pager to Mute mode after listening to a message.

2

4

5

Locking Slide

Channel Select Switch

Slide Switch

3

Reviews:

Related manuals for SCEPTAR