MICROWAVE DETECTOR

Sensor Adjustment

Saxby Lighting. BH17 7BY

V1 08/11/2019

We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
For your safety, always switch off the power supply before changing lightbulbs, or cleaning.

Care and Safety

Technical data

Conformity with all relevant EC Directive requirements.

The power supply is Double Insulated and does not require connection to an Earth circuit.

Waste electrical products should not be disposed of with household waste. Please recycle where facilities

exist. Check with your Local Authority or local store for recycling advice. 

This product is rated at IP20.

IP

20

This product is not suitable for dimming.

AC

LOAD

AC

LOAD

Supply Voltage: 240V~   

 

Detection Range: 360º

Power Frequency: 50Hz   

 

Detection Distance: Max. 8m (radius)  

HF System: 5.8GHz CW radar, ISM band 

Power Consumption: approx 0.9W

Ambient Light: <10-2000LUX (adjustable) 

Transmission Power: <10mW

Time-Delay: Min.10sec±3sec 

 

Installing Height: 1.5~4m

                   Max.15min±3min 

 

Detection Motion Speed: 0.6~1.5m/s 

Rated Load: 2000W
                   1000W

• 

Turn the TIME knob anti-clockwise on the minimum (10s). Turn the LUX

    knob clockwise on the maximum (+).

• 

When you switch on the power, the light will be on at once. And

   10sec±3sec later the light will be off automatically. Then if the sensor
    receives induction signal again, it can work normally.

• 

When the sensor receives the second induction signals within the first

   induction, it will  restart to time from the moment.

• 

Turn LUX knob anti-clockwise on the minimum (-). If the ambient light is

   less than 10LUX (darkness), the inductor load could work when it receives
   induction signal.

Note: when testing in daylight, please turn LUX knob to 

+

 position,

otherwise the sensor lamp could not work! If the lamp is more than 60W, the
distance between lamp and sensor should be 60cm at least. 