MICROWAVE DETECTOR
Sensor Adjustment
Saxby Lighting. BH17 7BY
V1 08/11/2019
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
For your safety, always switch off the power supply before changing lightbulbs, or cleaning.
Care and Safety
Technical data
Conformity with all relevant EC Directive requirements.
The power supply is Double Insulated and does not require connection to an Earth circuit.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities
exist. Check with your Local Authority or local store for recycling advice.
This product is rated at IP20.
IP
20
This product is not suitable for dimming.
AC
LOAD
AC
LOAD
Supply Voltage: 240V~
Detection Range: 360º
Power Frequency: 50Hz
Detection Distance: Max. 8m (radius)
HF System: 5.8GHz CW radar, ISM band
Power Consumption: approx 0.9W
Ambient Light: <10-2000LUX (adjustable)
Transmission Power: <10mW
Time-Delay: Min.10sec±3sec
Installing Height: 1.5~4m
Max.15min±3min
Detection Motion Speed: 0.6~1.5m/s
Rated Load: 2000W
1000W
•
Turn the TIME knob anti-clockwise on the minimum (10s). Turn the LUX
knob clockwise on the maximum (+).
•
When you switch on the power, the light will be on at once. And
10sec±3sec later the light will be off automatically. Then if the sensor
receives induction signal again, it can work normally.
•
When the sensor receives the second induction signals within the first
induction, it will restart to time from the moment.
•
Turn LUX knob anti-clockwise on the minimum (-). If the ambient light is
less than 10LUX (darkness), the inductor load could work when it receives
induction signal.
Note: when testing in daylight, please turn LUX knob to
+
position,
otherwise the sensor lamp could not work! If the lamp is more than 60W, the
distance between lamp and sensor should be 60cm at least.