Wiring and Connectors

RS-232 Wiring

RS-422/RS-485 Wiring

RJ-45 to DB9 Adapters

Savant uses RJ-45 connectors for RS-232/422/485, other manufacturers control 

systems may use the standard DB9.  To make connection easy, Savant offers RJ-45 to 

DB9 adapters in a variety of configurations that can be used to connect to SmartAudio 

for RS-232/422/485 control.  Be sure and choose the adapter that provides a proper 

connection to the control systems RS-232/422/485 port.  Refer to the manufacturers 

support for the control systems configuration.

For more information on Savant RJ-45 to DB9 adapters, see 

RS-232 Conversion to 

DB9 and RS-422/485 Pinout

 application note located on the 

Savant Portal

.

 

 

IMPORTANT!

 If you are using RJ-45 to DB9 adapters not supplied by Savant:

• Ensure that any wires required for communication/control are terminated within the 

adapter.

• Ensure that all wires NOT required for communication/control are NOT terminated in 

the connecter.

• Ensure that the unused wires in the connector are cut to prevent them shorting out, as 

they are still terminated in the RJ-45 connector on the controller side

IR Wiring

IR connections are made using 4-pin Screw Down Plug-in Connectors supplied with 

matrix or receiver.  The wire slips into the hole and locks screw located at the top of the 

connector.

 

 IMPORTANT! IR Wiring Precautions

• Wire runs longer than 15 feet (4.6 meters) can experience an interruption in IR signal 

that can degrade IR performance.  Ensure that all IR emitters are within 15 feet (4.6 

meters) from the chassis or receiver location.

• Use of 3rd party flashing IR emitters with Talk Back is not recommended.  These types 

of emitters can draw voltage away from the IR signal that can degrade IR 

performance.

IR Port Connector Pinout

GPIO Connector Pinout

Network Requirements

Savant requires the use of business class/commercial grade network equipment 

throughout the network to ensure the reliability of communication between devices.  

These higher quality components also allow for more accurate troubleshooting when 

needed.
Connect all Savant devices to the same local area network (LAN), virtual local area 

network (VLAN), or subnet as the host.  Savant recommends not implementing any 

type of traffic or packet shaping in your network topology for the Savant devices as this 

may interfere with performance.

Network Configuration

To ensure that the IP address of the SSA-4012 will not change due to a power outage, 

a static IP address or DHCP reservation should be configured.  Savant recommends 

using DHCP reservation within the router.  By using this method, static IPs for all 

devices can be managed from a single UI avoiding the need to access devices 

individually.

DHCP Reservation

Setting DHCP reservation varies from router to router.  Refer to the documentation for 

the router on how to configure DHCP reservation.

Network Changes

The SSA-4012 requires rebooting after connecting to a new network, changing routers, 

or if the IP address range is changed in the current router.  If the SSA-4012 is not 

rebooted after making network changes, the controller will not sense the changes 

made to the network or IP settings.  The 

Status LED

 (

Front Panel

  item 3) will start to 

flash and reports will be logged within System Monitor.

To reboot the controller preform one of the following steps.

Reset IP via Front Panel Button

See 

Front Panel

  item 1.

Cycle Power

Disconnect the controller from the AC power source for 15 seconds, and then 

reconnect.

Hot Plug the Ethernet (LAN) Connection

Disconnect the Ethernet (LAN) connection from the controller for 15 seconds, and 

then reconnect.

Checking and Replacing the Fuse

 

ELECTRIC SHOCK HAZARD!

 Disconnect the unit from AC power by removing 

the power cord from the AC outlet and the unit before replacing the fuse.

 

IMPORTANT! 

The orientation of the cartridge within the unit and location of the 

fuse within the cartridge are crucial to proper operation.  Make note of the 

orientation of the cartridge and the fuse location within the cartridge before 

removing.

1. Disconnect the unit from AC power by removing the power cord.
2. Open the fuse cover on the AC power input using a flat head screwdriver or similar 

thin flat head tool.  This will allow access to the fuse cartridge.

3. Using a flat head screwdriver or similar thin flat head tool, gently loosen the cartridge, 

and pull the cartridge out of the unit slowly.  As the cartridge is removed, make note of 

the orientation as it is important to proper operation.

Tip:

 Mark the Chassis, and Fuse Holder with a marker in order to align when 

replacing.

4. Remove the old fuse from the cartridge, and discard.
5. Gently place the new fuse in the cartridge, and place the cartridge part way into the 

receptacle aligning it as defined in the diagram.

6. Gently press on the cartridge the rest of the way until it seats into the terminals at the 

rear of the slot.

Note:

 If any resistance is encountered during seating the cartridge, DO NOT apply 

more pressure.  Stop pressing on the cartridge, remove it, verify the orientation, and 

repeat step.

Additional Documentation

Additional Documentation is available on the 

Savant Portal

.

Knowledge Base  >  Savant Hardware  >  SSA-4012

Copyright © 2014 Savant Systems, LLC. SAVANT and RacePoint Blueprint are trademarks of Savant Systems, LLC.

All brand names, product names and trademarks are the property of their respective owners. 

Savant Systems, LLC reserves the right to change product specifications without notice.

SSA-4012-00 | 009-1201-01 | 140707

Savant Confidential and Proprietary

2 of 2