This Quick Reference Guide provides all the steps necessary to install the SSA-4004-
xx. The SSA-4004 is a 6 x 4 audio matrix switcher and controller in a 1U rack-
mountable design.
Box Contents
(1) SSA-4004-00
(1) Installation Kit (075-0144-xx)
(2) 1U Rack Mounting Brackets (071-0603-xx)
(4) Phillips Screws for Brackets (M3 x 8MM Flat) (039-0017-xx)
(2) 6-Pin Screw Down Plug in Connector (028-9352-xx)
(1) Power cord C13 (6 feet) (N. America) (064-0079-xx)
or appropriate international power cord
(1) Quick Reference Guide (this document)
Required System Component
(1) Savant Smart Host or Savant Pro Host
Specifications
Environmental
Environmental
Temperature
32° to 104° F (0° to 40° C)
Humidity
10% to 90% Relative Humidity (non-condensing)
Cooling
3 cubic feet per minute (CFM) recommended.
Maximum BTUs
61 BTUs per hour
Dimensions and Weight
Dimensions and Weight
Height
1.71 in (4.34 cm)
Width
17.30 in (43.94 cm)
Depth
8.69 in/22.08 cm
Weight
Net: 5.25 lb (2.38 kg)
Shipping: 7.8 lb (3.54 kg)
Rack Space
1U
Power
Power
Input Power
100-240V AC, 50/60 Hz, (1.8 Amp maximum)
Nominal Power
12 watt
Maximum Power
18 watt
Stereo Preamp Parameters
Stereo Preamp Parameters
Total Harmonic Dist
Noise (THD+N)
<0.005%, 20Hz - 20KHz, -100dB@1kHz
Dynamic Range
115dB
Signal-to-Noise Ratio (SNR)
>105dB
Frequency Response
20Hz - 20kHz +0dB +/-0.1dB
Output Impedance
50 ohms
Crosstalk
<-80dB
Supported Sample Rates
44.1 kHz/48 kHz/96 kHz/192 kHz at 16-bit or 24-
bit resolution
Compliance
Compliance
Safety and Emissions
FCC Part 15 | S Mark | CE Mark | C-Tick
RoHS
Compliant
Minimum Supported Release
Minimum Supported Release
Savant OS
da Vinci 6.0.1
Front Panel
1
Reset button (hole)
Resets Static IP address. Insert pin into hole for 5 seconds
to reset.
2
Power Bi-color LED
Green
indicates the system has adequate power and is
operating normally.
Red
indicates the system is in standby mode. In standby
most of the Controller circuitry is powered down.
Off
indicates that the system is getting no power.
3
Status Bi-color LED
Green
indicates the Host has established
communications with the embedded system.
Green flashing
indicates the embedded system is ready
(running with DHCP IP address), but the Host has not
established communications with the embedded system.
Off
indicates the embedded processor is resetting or is
powered up; and is booting the embedded firmware.
Red
indicates the Host has determined the firmware
needs to be updated, but a problem occurred during the
process that will initiate a reset.
Red flashing
indicates the embedded firmware is
running, but has not received a DHCP IP Address.
Amber
indicates the Host is currently updating the
embedded firmware.
Amber
flashing
indicates the embedded system has a
valid link-local IP Address and is waiting to connect to
the Host.
Hardware Failure
If the Controller has a hardware failure, the Status LED
indication will be interrupted every 3 seconds with a solid
red indication. For example, if the LED is flashing green
when a hardware failure occurs, the LED will flash green,
solid red, etc in 3 second intervals.
4
RS-232 LED
Green
indicates RS-232 serial port data activity.
Off
indicates no RS-232 serial port activity.
5
GPIO LED
Green
indicates GPIO port signal activity.
Off
indicates no GPIO port activity.
6
On/Off button (hole)
Insert pin into hole for about 5 seconds to place into standby
mode. The Power LED turns red. Insert the pin again for
about 1 second to take system out of standby mode. The
I/O
power switch on the back of Controller must be On (
I
) to
enable this function. To turn the power off for the entire
system, use the switch on the rear panel.
7
HDMI LED
HDMI not included with the SSA-4004 - This LED is not
functional.
8
IR LED
Green
indicates IR port signal activity.
Off
indicates no IR port activity.
Rear Panel
1
Ethernet
RJ-45 10/100 Base-T, auto-negotiating port with Link/
Activity and Speed LEDs.
2
RS232/422/485
(1-4)
RJ-45 ports used to transmit and receive serial binary
data transmission.
3
GPIO (1-4)
General Purpose Input and Output ports. Uses 6-pin
screw-down connector.
The digital GPIO ports are binary I/O ports used for
contact closure, trigger (output), or detect (input). The
COM pin is used for common ground.
3
GPIO Input
When configured as an input, the port detects a voltage
present. GPIO inputs can safely detect the presence of a
voltage 0-30V DC with a threshold of approximately 2.4V
DC.
3
GPIO Output
When configured as an output, a GPIO port outputs a
voltage below 12V DC. The maximum current per port is
150 milliamps. The combined maximum current for all
GPIO outputs is 550 milliamps. An overcurrent condition
shuts down the output if that number is exceeded.
4
Stereo In
4 Analog Audio Inputs (4 Right and 4 Left)
5
Stereo Out
4 Stereo line-level audio outputs (4 Right and 4 Left RCA
jacks)
6
Fuse
100-240V, 2.5A—Fast acting fuse. This is field-
replaceable.
7
Link/Activity LED
Green
indicates an Ethernet link has been established.
Green flashing
indicates Ethernet activity.
Off
indicates an Ethernet link has not been established.
8
Ethernet Speed
LED
Green
indicates an Ethernet speed of 100 Mb.
9
IR (1-3)
Infrared transmitter ports. Uses 6-pin screw down
connector. (3.81 mm each).
10
Digital Audio In
Receives stereo PCM signal from TosLink digital audio
connection.
11
I/O
On/Off switch -
I is used to power the controller to the On state.
O is used to power the controller to the Off state.
12
Input Power
100-240V AC, 50/60 Hz, 1.8 Amp
SSA-4004-00 | 009-1199-00 | 140509
Savant Confidential and Proprietary
1 of 2
SmartAudio 6 x 4 Audio Matrix
(SSA-4004)
Quick Reference Guide
Scan this QR code for additional