Accessing a *.prg File from a Legacy Controller
A LiteWare
*.prg
file is required for a SmartLighting system to function properly. This file type must be
exported to the Savant SmartLighting controller after retrieving the file from a Central Control Unit (CCU).
Before the
*.prg
file can be exported to a SmartLighting controller, the file must first be extracted from a
CCU.
The
*.prg
file type is native to a FIVEk CCU (or 5000LC), but the standard and compact CCUs do not use
*.prg
files. The standard and compact CCU definition files—
*.def
and
*.cdf
(respectively)—must be
converted to
*.prg
files.
Note that the CCU communicates with LiteWare using either an Ethernet or a serial connection.
To extract the LiteWare
*.prg
file from a FIVEk CCU (or 5000LC), do the following. The procedure for
converting a
*.def
file or
*.cdf
file is at the end of this procedure. See
1. Open LiteWare 5.1 or higher.
2. Select
Control Panel
(shown circled in the next screenshot).
3. Click
No
on this dialog box:
140915 009-0885-01 Savant SmartLighting Control Conversion Application