background image

SHR-2000-00  |  009-1909-01  |  200123 

Copyright 2020 Savant Systems, LLC

45 Perseverance Way, Hyannis, MA 02601 

Savant.com

  |  508.683.2500

1     of     2

Front Panel

Power

Status

A

B

C

A

Power LED

Green

: System has power and is operating 

normally.

Off

: System is not receiving power.

B

Status LED

Off

: Disconnected from power supply.

Amber

: Host is booting/rebooting and is 

disconnected from the network.

Green

: Connected to the local network and is 

assigned an IP Address.

C

Mounting 

Points

Threaded insert for use with optional rack 

mounts

Box Contents

(1)  Savant® Smart Host Rack Mountable - (SHR-2000-00)
(1)  Install Kit (075-0223-xx)
 (1) 

5V DC 3A Power Supply  

 

 

with Quick Change AC Adapters ( 025-0216-xx)

 

(2)  6-pin Screw Down Plug-in Connector Black (028-9352-xx)

 

(2)  3-pin Screw Down Plug-in Connector Black (028-9351-xx)

(1)  Product and Regulatory Insert (009-1781-xx)

Specifications

Environmental

Temperature

32° to 104° F (0° to 40° C)

Humidity

10% to 90% Relative Humidity (non-condensing)

Cooling

10 CFM

Maximum BTU

34.1 BTU/hr

Dimensions and Weights

Height

1.6 in (4.15 cm)

Width

8.5 in (21.50 cm)

Depth

3.7 in (9.33 cm)

Weight

Net: 1.4 lb (0.64 kg)

Shipping 2.3 lb (1.05 kg)

Rack Space

1U

Power

Input Power

5V DC 3A

Maximum Power

15 watts

Power over 

Ethernet (PoE)

IEEE 802.3af

Regulatory

Safety and 

Emissions

FCC Part 15

CE

C-Tick

RoHS

Compliant

Minimum Supported Release

Savant Software

da Vinci 9.2

Chassis Installation

The Smart Host can be installed on a solid, flat, level surface such as a 

table, cabinet, or shelf. The location should be dry, well ventilated, and 

out of direct sunlight.

Rack

The optional RMB-PAVAM2F-xx or RMB-PAVAM2-xx allows two 

devices to be mounted side by side. For example a Smart Host can 

be mounted next to a PAV-AIM7C. This rack is compatible with all 

standard 19-inch National Electrical Manufacturers Association (NEMA) 

rack mounts.
The instructions below show the RMB-PAVAM2F-xx, both brackets 

install the same way they just face different directions.
1.  Align the bracket with the Smart Host mounting points.

2.  Attach using the screws provided with the bracket. 

 

Network Configuration

To ensure the IP Address will not change due to a power outage, a 

static IP Address or DHCP reservation should be configured. Savant 

recommends using DHCP reservation within the router. By using this 

method, static IP Addresses for all devices can be managed from a 

single UI, avoiding the need to access devices individually.
Setting DHCP reservation varies from router to router. Refer to the 

documentation for the router to configure DHCP reservation.

Refreshing the IP Connection

After connecting to a new network, changing routers, or if the IP 

Address range in the router was changed, the IP connection should be 

refreshed. To refresh the IP connection, do one of the following:

 

Hot Plug the Ethernet (LAN) Connection

 

Cycle power

Savant® Smart Host Rack Mountable

Quick Reference Guide

Reviews: