Savant SLN-88BT Quick Reference Manual Download Page 1

The Savant® SmartLink 8 (SLN-88BT) Quick Reference Guide provides information necessary 

to install the SLN-88BT. The SLN-88BT is an 8x8 HDMI® matrix switch that uses Cat5e, Cat6, or 

Cat7 cabling.The SLN-88BT is based on HDBaseT

®

 5Play™ technology.

Box Contents

(1) SmartLink (SLN-88BT) 
(1) Installation Kit (075-0098-xx):

(1) Side-Mounting Brackets

(4) M3 x 8MM Flat Phillips Screws (039-0017-xx)

(1) Power cord C13 (6 feet) (N. America) (064-0079-xx) or appropriate international power 

cord

(4) Rubber Chassis Feet (093-0351-xx)

(4) Screws for Rubber Feet (039-0005-xx)

(1) Quick Reference Guide (this document)

Specifications

Environmental

Environmental

Temperature

32° to 104° F  (0° to 40° C)

Humidity

10% to 90% Relative Humidity (non-condensing)

Cooling

25 cubic feet per minute (CFM) recommended.

Maximum BTUs

512 BTUs per hour

Noise

Normal Operation condition: 52 dB Average

Dimensions and Weight

Dimensions and Weight

Height

5.21 in/13.23 cm

Width

17.30 in/43.94 cm

Depth

12.94 in/32.88 cm

Weight

20.50 lb /  9.29 kg

Rack Space

3U

Power

Power

Input Power

100-240V AC, 50/60 Hz, (1.8 Amp maximum)

Input Power

Standard 3 prong IEC C14 connector

Nominal Power

North America: 150 Watts (40 VA) for 120V AC, 60Hz

Nominal Power

Europe: 150 Watts (50 VA) for 230V AC, 50Hz

Maximum Power

North America: 200 Watts (40 VA) for 120V AC, 60Hz

Maximum Power

Europe: 200 Watts (50 VA) for 230V AC, 50Hz

Power Connection

IEC 320 power connector with 3-pole detachable power 

cord

Compliance

Compliance

Safety and Emissions

FCC Part 15  |  S Mark  |  CE Mark  |  C-Tick

RoHS

Compliant

1

2

3

4

Front View of SLN-88BT

1

Reset

 (hole)

Insert pin into hole for about 10 seconds to reset the Static IP 

address.

2

Power

 LED

Green

 indicates the system has adequate power and is 

operating normally.

Red

 indicates the system is in stand-by mode. The Controller 

hardware has power, but the embedded processor is shut off 

and in the standby mode.

Off indicates that the system is not receiving power.

3

CPU Status

 LED

Green

 indicates the Host has evaluated the firmware currently 

running and determined it is up to date.

Green flashing

 indicates the embedded system is ready 

(running with DHCP IP address), but the embedded processor 

has not established communications with the embedded 

system.

Off indicates the embedded processor is resetting or is 

powered up; and is booting the embedded firmware.

Red

 indicates the Host has determined the firmware needs to 

be updated, but a problem occurred during the process that 

will initiate a reset.

Red flashing

 indicates the embedded firmware is running, but 

has not received a DHCP IP Address.

Amber

 indicates the Host is currently updating the embedded 

firmware.

Amber flashing

 indicates the embedded system has a valid 

link-local IP Address and is waiting to connect to the Host. 

4

On/Off 

(hole)

Insert pin into hole for about eight seconds to place in standby 

mode. Insert the pin again for about 1 second to take system 

out of standby mode. The I/O power switch on the back of 

Controller must be On (I) to enable this function. To turn the 

power off for the entire system, flip the switch to Off (O).

!

1

2

4 5 6

3

7

8

9

10

11

12

13

14

Rear View of SLN-88BT

1

HDMI Output 

(8) 19-pin Type A HDMI female; digital video/audio outputs; 

signal types HDMI, DVI—compatible with DVI/D (requires DVI 

to HDMi adapter, not included), allowing DVI/D source signal 

to be passed to displays. Limited to 185 MHz pixel clock.

2

Link

(8) 8-pin RJ45 female, shielded; HDBaseT compliant.Connect 

to SmartLink inputs of SmartLink receivers or to HDBaseT 

devices via single Cat5e, Cat6, or Cat7; Extends video and 

bidirectional RS-232, IR and audio signals through a single 

category cable.

3

LAN 

(8) RJ45 10/100 Base-T, auto-negotiating port with Link/

Activity LEDs.

4

Fuse 

100-240V, 2.5A—Fast acting fuse. This is field-replaceable.

5

I/O 

On/Off switch -  

I is used to power the controller to the On state. 

O is used to power the controller to the Off state.

6

Input Power 

100-240V AC, 50/60 Hz

7

HDM Input

(8) 19-pin Type A HDMI female; digital video/audio inputs; 

signal types HDMI/DVI

8

S/PDIF Digital Coax 

(8) S/PDIF Outputs (Digital Coax, RCA connectors)—for 

example, can be used in conjunction with the SmartAudio 16 

SSA-1620 Audio Matrix Switcher

9

RS232

(8) RJ45 female-connector ports used to transmit and receive 

serial binary data.

10

IR 

(8)IR Inputs and (8) IR Outputs - Uses four-pin screw down 

connectors (3.81mm).

The IR IN ports receive IR commands from a Savant controller 

with IR control or third party IR control box and send them over 

the Cat5e, Cat6, or Cat7 port (SmartLink) to the distant ends 

IR output port to control devices in that zone. Conversely, IR 

OUT ports can drive an IR emitter(blaster) with IR commands 

received from the distant ends IR IN port.

NOTE: IR IN and OUT ports are 5V tolerant only.

11

Link/Activity LED 

Green indicates an Ethernet link has been established.

Green flashing indicates Ethernet activity.

Off indicates an Ethernet link has not been established.

12

Speed LED 

Green indicates an Ethernet speed of 100 Mb.

13

LAN 

(1) RJ45 10/100 Base-T, auto-negotiating port with Link/

Activity LEDs (same as Items 11 and 12). Through this 

Ethernet port, the SLN-88BT provides a single-point 

connection to a home network or corporate LAN.

14

Debug / RS232 

(1) RJ45 female-connector serial port port—typically used for 

debug or optionally for control from a Savant Controller or third 

party control box

Savant SmartLink 8

(SLN-88BT)

Quick Reference Guide

009-1000-00

SLN-88BT-00

080813

Document based upon target specifications. Specifications subject to change prior to final product release.

Reviews: