background image

Stand Alone Energy Monitor  |  009-1836-02

45 Perseverance Way, Hyannis, MA 02601

Copyright 2020 Savant Systems, Inc  |  200728

1     of     4

Savant.com

  |  508.683.2500

Savant® Stand Alone Energy Monitor (SEM-2015)

Quick Reference Guide

Box Contents

(1)  Stand Alone Energy Monitor

(1)  Install Kit (075-0227-xx)

 

(1)  Universal Din Rail Mounting Clip (015-0255-xx)

 

(1)  Power Supply (025-0192-xx)

 

(1)  6-Pin Screw Down Connector (028-0664-xx)

 

(15)  2-Pin Screw Down Connector (028-0884-xx)

 

(4)  #6x1/4 PH Flat Screws (039-0143-xx)

(1)  Product Regulatory Insert (009-1950-xx)

Accessories (sold separately)

 

SEM-VT01 - SmartEnergy Voltage Sensor

 

Split Core Current Transformers (Clamp-on) with 8ft leads.

 

SEM-020A5 

20 Amps 

5 Pack

 

SEM-050A5 

50 Amps  

5 Pack

 

SEM-150A1 

150 Amps 

1 Pack

 

SEM-150A5 

150 Amps 

5 Pack

 

SEM-250A1 

250 Amps 

1 Pack

 

SEM-400A1 

400 Amps 

1 Pack

 

SEM-600A1 

600 Amps 

1 Pack

Specifications

Environmental

Temperature

32° to 104° F (0° to 40° C)

Humidity

10% to 90% Relative Humidity (non-condensing)

Dimensions and Weight

Height

9.5 in (24.13 cm)

Width

9.7 in (24.64 cm)

Depth

3.3 in (8.38 cm)

Weight

Shipping: 2.65 lb (1.2 kg)

Power

Input Power

5V DC

Nominal Power 

3W (10W max)

Regulatory

Safety and 

Emissions

FCC Part 15B 

CE Mark 

RoHS

Compliant

Minimum Support Requirements

Software  

Release

da Vinci 9.1

Important Information

 

All wiring in the United States must be installed in accordance with 

the latest adopted edition of the National Electrical Code (ANSI/

NFPA 70, NEC).

 

All wiring in Canada must be installed in accordance with the latest 

adopted edition of the Canadian Electrical Code (CSA C222.2 CEC, 

Part 1) and any provincial or local requirements. 

 

Savant’s largest Current Transformer supports wire up to 500 MCM 

(this with jacket is just under 1 inch).

 

TIP!

 MCM refers to circular mils and is often used for wire larger 

than the AWG measurement accommodates.

 

Maximum length for leads on each current transformer should not 

exceed 8 feet. Longer lengths will cause inaccurate readings. 

 

If required, the leads on the current transformers can be shortened.

Left Side Panel

5 VDC

Power Input

 - Connect the supplied power 

adapter between the 5V DC port and a surge 

protected (120-240V AC, 50/60 Hz) outlet.

Ethernet

8-Pin RJ 45 port. 10/100/1000 BaseT auto-

negotiating port with link activity LEDs

Status

Blinking Red

 - Embedded firmware is running 

but has not received an IP Address.

Solid Green

 - Connected to the local network 

and communicating with the Savant System 

Host.

Reset

Press and release to perform a hard reset. Status 

LED will illuminate while button is pressed.

Device Reset

:

1.  Disconnect power.

2.  Reconnect power wile holding the reset 

button for 40 seconds. 

Device will reboot clearing its configuration 

and resetting its password.

 (Ground)

Chassis Ground (optional)

Right Side Panel

B

A

N/A

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

C

VT Connections

Voltage Transformer

 - (3) Voltage sensor input 

ports. Input port for the SEM-VT01 voltage 

sensor.

CT Connections

Current Transformer

 - (15) Input ports for each 

Current Transformer installed in the system. 

Mounting

The SEM-2015 can be mounted to either a wall or similar using the pre-

installed Mounting Bracket and the included #6x1/4 PH Flat Screws. 

Also the device can be mounted to a Universal Din Rail by removing 

the Mounting Bracket and attaching the included Universal Din Rail 

Clip on the bottom of the device. For more information on mounting 

see the Standalone Energy Monitor Deployment Guide on the 

Savant 

Customer Community

.

Reviews: