The Savant
®
CLI-8000 and CLI-8000A eight zone Thermostat Processing Units
(TPU) are at the heart of the Savant
®
Centralized Climate Control system. Through
communications with a number of remote sensors and optional user interfaces, the
Thermostat Processing Unit can manage up to eight heating, ventilation, and air
conditioning (HVAC) systems. The system is easily integrated with most leading
HVAC systems and can be designed as one part of a complete Savant
®
Control
System solution.
The CLI-8000 version is configured using the keypad and display located on the front
panel.
The CLI-8000A version is configured using a climate application loaded onto an
Android™ based tablet (Android is a trademark of Google Inc). The tablet, which is
installed into the front cover of the TPU, incorporates a touch screen interface with an
elegant climate control application for setting up, viewing, and controlling each
climate zone independently.
Once installed and configured, either system the can be integrated to add monitoring
and control through an iOS device such as iPad
®
or iPod
®
.
This Quick Reference Guide provides the information necessary to install the
CLI-8000/8000A as well as information on wiring to each of the optional and required
components of the Savant HVAC solution.
Box Contents
(1) CLI-8000 or CLI-8000A (Includes all mating connectors from front panel)
(1) Samsung Galaxy Tab 3 (CLI-8000A only)
(1) Quick Reference Guide (this document)
Related Components
Savant
®
Host
Savant
®
Controller SSC-0008-XX, SSC-0025-XX
External 120V AC to 24V AC Transformer, PWR-2440-XX
Optional Remote Sensors
Savant
®
SST-TEMP1 - Remote Indoor Sensor
Savant
®
SST-OTEMP1 - Remote Outdoor Sensor
Savant
®
CLI-THFM1 - Remote Humidity/Temperature Smart Sensor
Savant
®
CLI-PLEN1C - Commercial Plenum Sensor (Heat duct sensor)
Savant
®
CLI-PLEN1R - Residential Plenum Sensor (Heat duct sensor)
Savant
®
CLI-SLAB1 - SLAB Sensor (Floor Heating Sensor)
Note:
Each zone on the CLI-8000/8000A supports communications with up to four
temperature sensors and two humidity sensors.
Specifications
Environmental
Environmental
Temperature
32° to 104°F
Humidity
10% to 90% Relative Humidity (non-condensing)
Dimensions and Weight
Dimensions and Weight
Height
12.17 inches (309.12 mm) with cover
Height
11.05 inches (280.67 mm) without cover
Width
15.48 inches (393.19 mm) with cover
Width
14.23 inches (361.44 mm) without cover
Depth
2.81 inches (71.37 mm) with cover
Depth
2.71 inches (68.83 mm) without cover
Weight
8.75 lb. / 4.0 kg
Power
Power
Power (Input)
24V AC (40VA) from external transformer
Power Draw
(Maximum)
CLI-8000 = 12W @ 24V AC
Power Draw
(Maximum)
CLI-8000A = 24W @ 24V AC
Cable Requirements
Cable Requirements
Relay Bank to
HVAC system
18 American Wire Gauge (AWG)
Standard HVAC wiring (RH, RC, W1, W, Y1, Y2, O, G, Aux)
Cable Requirements (Sensors)
Cable Requirements (Sensors)
Data Sensor
Bus (1-Wire)
24 AWG (Cat 5) 600 feet (182 m) maximum (cumulative)
Remote Sensor 24 AWG (Cat 5) 500 feet (152 m) maximum
Compliance
Compliance
Safety and
Emissions
FCC Part 15
RoHS
Compliant
Additional Info
Additional Info
RS-232
Baud Rate = 19200
CLI-8000/8000A Front Panel View
Item
Item
Description
A
Ethernet
Reserved for Future Use
B
HVAC Relays
Each relay bank or zone gets wired to an HVAC
system. The CLI-8000/8000A supports wiring up to
eight individual HVAC systems.
C
RS-232
Connect cable from the RS-232 port to a Savant
Controller. Communication between the controller
and the CLI-8000/8000A is achieved over the
RS-232 connection. RS-232 supports 19200 baud.
D
Station Bus
Reserved For Future Use
E
Console
Mini USB (Mini-B) female connector (Serial UART);
Debug terminal
F
DSB/1-Wire
The DSB/1-Wire Connector connects to the Data
Sensor Bus, which is a serial bus based on the 1-
Wire protocol. The CLI-THFM1 smart sensor
communicates over the Data Sensor Bus through
this connection. Up to two smart sensors per zone
can be configured with a total of eight per system.
G
Display/Keypad
Monitors and configures the system. Use the keypad
to scroll through the available menus and configure
each zone.
H
Remote Sensors
Indoor, Outdoor, Slab, and Plenum two-wire
temperature sensors are connected here. A
maximum of two per zone is supported.
I
Input Power
(Access)
Remove the power input access screw and remove
the associated panel. This will give user access to
the power supply board for wiring the 24V AC input
power.
J
Zone LEDs
The Zone LED’s indicate which zone has been
selected via the keypad for configuration.
K
Input Power
(24V AC)
System is powered by 24V AC power source. Power
cable is fed through
½
inch cable restraint (not
included) installed at bottom of box. Input power is
wired to a two position screw terminal block on the
power supply board.
L
Analog Control
Reserved for Future Use
M
USB
The USB port connects to the optional Android™
based tablet. Communication between the tablet and
the CLI-8000A version of TPU is achieved through
the USB port.
N
Smart Connect
Maintenance functions such as firmware upgrades
are achieved through the Smart Connect
connection. Requires SCA-CONF-XX or SCA-
CONFL-XX Smart Connect cable.
Thermostat Processing Unit
(CLI-8000-00 / CLI-8000A-00)
Quick Reference Guide
Scan this QR code for additional
product information.
009-1090-01
CLI-8000-00
CLI-8000A-00
009-1090-01
31314
Savant Confidential and Proprietary
1