background image

 
 
 

 

Instruction Manual 

 

FT 1K 

 

 

FT_SO-BA-e-1111  

1

 

SAUTER GmbH 

Tieringerstr. 11-15, D-72336 Balingen  

                   Tel: +49 (0) 7433 9976 174 

[email protected] 

www.sauter.eu 

 
Thank you for buying a SAUTER force gauge. We hope 
you are pleased with your high quality force gauge with its 
big functional range. If you have any queries, wishes or 
helpful suggestions, do not hesitate to call our service 
number. 
 
„Sensor Outside“ means the cell is outside the body. 
 
 
 
 
 
 
 
 

1. 

Included in Delivery 

 

- SAUTER 

FT 

- Carrying 

Case 

- Standard 

Attachments 

 

 

 

 
 
3.1. Universal Sensing Head 
3.2. LCD Display  
3.3. FAST Indicator 
3.4. FAST / SLOW Button 
3.5. LCD Reverse Display Button 
3.6. Zero Button 
3.7. Unit switch (N, g, oz) 
3.8. Power Off/On/Peak Hold 
3.9. Mounting holes/fixing Screws 
3.10. Battery Cover/ Compartement 
3.11. – 3.15. Standard Attachments  
3.16. LCD Backlight Button 
3.17. 9V DC Power Adapter Input Socket 
3.18. RS 232 Output terminal 
 

 

2. Warning 

 
2.1 Intended use 
The instrument you have acquired serves to determine the 
measuring value of the material to be measured. It is 
intended to be used as a “non-automatic“ instrument, i.e. 
the material to be measured is manually and carefully 
attached at the instrument. The measuring value can be 
read off after a stable measuring value has been obtained. 

Sensor 

Outside 

2.2 Inappropriate use 
Do not use the instrument for dynamic measuring. In the 
event that small quantities are removed or added to the 
material to be 
measured, incorrect measuring results can be displayed 
due to the “stability compensation“ in the instrument. 
(Example: Slow draining 
off of liquid from a container suspended from the 
instrument). Do not attach a continuous load. This can 
damage the measuring 
unit as well as the parts, relevant to safety. 
 
Prevent jolts, torsion and oscillation (e.g. by appending 
slopingly) of all kinds. Be sure to prevent overloading the 
instrument in excess of the stated maximum load (max.), 
minus any tare weight that may possibly exist. This could 
damage the instrument (risk of breakage). 
Important: 
• Always make sure that there are no people or materials 
below the load that could be injured or damaged! 
• The instrument is not suitable for measuring people. Do 
not use as baby scales! 
• The instrument does not comply with the medical product 
law (MPG). 
Never operate the instrument in hazardous locations. The 
series design is not explosion-proof. Structural alterations 
may not be 
made to the instrument. This can lead to incorrect 
measuring results, faults concerning safety regulations as 
well as to destruction 
of the instrument. The instrument may only be used in 
compliance with the described guidelines. Varying areas of 
application/ 
planned use must be approved by SAUTER in writing. 
2.3 Guarantee 
The guarantee is not valid following 
• non-observation of our guidelines in the operating 
instructions 
 
• use outside the described applications 
• alteration to or opening of the device 
• mechanical damage and damage caused by media, 
liquids 
• natural wear and tear 
• inappropriate erection or electric installation 
• overloading of the measuring equipment 
2.4 Monitoring the test substances 