Instruction Manual
FT 1K
FT_SO-BA-e-1111
1
SAUTER GmbH
Tieringerstr. 11-15, D-72336 Balingen
Tel: +49 (0) 7433 9976 174
www.sauter.eu
Thank you for buying a SAUTER force gauge. We hope
you are pleased with your high quality force gauge with its
big functional range. If you have any queries, wishes or
helpful suggestions, do not hesitate to call our service
number.
„Sensor Outside“ means the cell is outside the body.
1.
Included in Delivery
- SAUTER
FT
- Carrying
Case
- Standard
Attachments
3.1. Universal Sensing Head
3.2. LCD Display
3.3. FAST Indicator
3.4. FAST / SLOW Button
3.5. LCD Reverse Display Button
3.6. Zero Button
3.7. Unit switch (N, g, oz)
3.8. Power Off/On/Peak Hold
3.9. Mounting holes/fixing Screws
3.10. Battery Cover/ Compartement
3.11. – 3.15. Standard Attachments
3.16. LCD Backlight Button
3.17. 9V DC Power Adapter Input Socket
3.18. RS 232 Output terminal
2. Warning
2.1 Intended use
The instrument you have acquired serves to determine the
measuring value of the material to be measured. It is
intended to be used as a “non-automatic“ instrument, i.e.
the material to be measured is manually and carefully
attached at the instrument. The measuring value can be
read off after a stable measuring value has been obtained.
Sensor
Outside
2.2 Inappropriate use
Do not use the instrument for dynamic measuring. In the
event that small quantities are removed or added to the
material to be
measured, incorrect measuring results can be displayed
due to the “stability compensation“ in the instrument.
(Example: Slow draining
off of liquid from a container suspended from the
instrument). Do not attach a continuous load. This can
damage the measuring
unit as well as the parts, relevant to safety.
Prevent jolts, torsion and oscillation (e.g. by appending
slopingly) of all kinds. Be sure to prevent overloading the
instrument in excess of the stated maximum load (max.),
minus any tare weight that may possibly exist. This could
damage the instrument (risk of breakage).
Important:
• Always make sure that there are no people or materials
below the load that could be injured or damaged!
• The instrument is not suitable for measuring people. Do
not use as baby scales!
• The instrument does not comply with the medical product
law (MPG).
Never operate the instrument in hazardous locations. The
series design is not explosion-proof. Structural alterations
may not be
made to the instrument. This can lead to incorrect
measuring results, faults concerning safety regulations as
well as to destruction
of the instrument. The instrument may only be used in
compliance with the described guidelines. Varying areas of
application/
planned use must be approved by SAUTER in writing.
2.3 Guarantee
The guarantee is not valid following
• non-observation of our guidelines in the operating
instructions
• use outside the described applications
• alteration to or opening of the device
• mechanical damage and damage caused by media,
liquids
• natural wear and tear
• inappropriate erection or electric installation
• overloading of the measuring equipment
2.4 Monitoring the test substances