Instruction Manual 
Digital Force Gauge 

 

 

 

 

SAUTER FK 

Version 1.4 
12/2016

 

GB 

 

 

 
 

FK-BA-e-1614 

 

 

PROFESSIONAL MEASURING 

Summary of Contents for FK 50

Page 1: ...ei 1 D 72336 Balingen E Mail info sauter eu Tel 49 0 7433 9933 199 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction Manual Digital Force Gauge SAUTER FK Version 1 4 12 2016 GB FK BA e 1614 PROFESSIONAL MEASURING ...

Page 2: ... have any queries wishes or helpful suggestions do not hesitate to call our service number Summarize 1 Scope of delivery 3 2 Working Conditions 4 3 Electrical power supply 4 4 Technical data 4 5 Operation 4 5 1 Display 4 5 2 Keyboard units 4 5 3 Display Return of 180 5 5 4 Measurements Track Mode 5 5 5 Peak Hold Function Peak Mode 5 6 Backside Fixing to a test stand 5 7 Warning notices 5 8 Adjustm...

Page 3: ...or inside signifies that the measuring cell is inside the housing of the display unit Conditions Measurement principles 1 Continuous measurement Track 2 Capture of the max value Peak Hold In this mode the max value is always captured during several consecutive mea surements Dimensions in mm Sensor Inside 195 mm LCD Force sensor M8 thread 83 m ...

Page 4: ...y power adapter cable 4 Technical data Accuracy 0 5 of Capacity Internal test frequency 1 000 Hz Overload protection 200 of max Dimensions L x W x H 195 x 82 x 35 mm Net weight ca 0 72kg 5 Operation 5 1 Display 1 Measuring Result 2 Measuring Units 3 Measuring Direction 4 Indication of PEAK Mode 5 2 Keyboard units ON OFF to switch on ON has to be pressed for about 1s MAX To change between Track mod...

Page 5: ...key 5 5 Peak Hold Function Peak Mode To activate please press MAX key 6 Backside Fixing to a test stand Mounting is possible on all SAUTER test stands by means of 4 x M3 screws 7 Warning notices Force measurements which are performed in an incorrect way can lead to serious injuries of living beings and damage of objects Therefore trained staff may practice them only Please avoid that forces are re...

Page 6: ...ent risk of breakage Attention Always make sure that there are no people or objects below the load which could be injured or damaged The instrument is not suitable for weighing people Do not use it as a baby scale The instrument does not comply with the medical product law MPG Never operate the instrument in hazardous locations The series design is not ex plosion proof Structural alterations may n...

Page 7: ...g the monitoring of instrument test substances and the test weights required for this Test weights and instruments can be adjusted quickly and reasonably priced in KERN s accredited DAkkS calibration laboratory return to national normal IMPORTANT Observe the information in the operating instructions Please read the instruction manual carefully before the initial operation even if you already have ...

Page 8: ... 00kg for FK 100 4 Put the corresponding weight at the loading hook Avoid trembling and keep still while holding the weight Hint hold device with both hands while shoring up your elbows on a table or desk or fix it at a solid object test stand 5 Hold position until F appears on the display In this case remove weight and adjustment is completed In case of E is displayed repeat step 1 to 5 until F a...