sauter CJ X467 User Manual Download Page 1

 

Sauter GmbH

 

Ziegelei 1 
D-72336 Balingen 
E-Mail: [email protected] 

Tel.:  +49-[0]7433- 9933-0 
Fax: +49-[0]7433-9933-149 
Internet: www.sauter.eu 

 
 
 

Data sheet / User manual 

 

 

 

SAUTER CJ X467 / CJ X468 

V. 1.0 
11/2020

 

GB 

 

                    

                                

 

CJ X467-CJ X468-BA-e-2010.docx 

Summary of Contents for CJ X467

Page 1: ...Ziegelei 1 D 72336 Balingen E Mail info kern sohn com Tel 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www sauter eu Data sheet User manual SAUTER CJ X467 CJ X468 V 1 0 11 2020 GB CJ X467 CJ X468 BA e 2010 docx ...

Page 2: ...5 2 CJ X468 4 6 Electrical connection 5 6 1 Cable diameter 5 6 2 Connection description 5 6 3 Connection of a 6 wire cell to a 4 wire terminal block 6 6 4 Grounding 6 7 Adjusting the balance 6 7 1 Corner adjustment 7 8 Small troubleshooting 7 8 1 The scale seems to indicate an incorrect weight 7 8 2 The corners indicate unequal weights 7 8 3 The displayed value drifts quickly 7 9 Declaration of co...

Page 3: ...th damage to property and personal injury Only trained and experienced personnel are allowed to use the junctions Never step under suspended loads For measuring cells with 4 wire connection the characteristic value changes by shortening or lengthening the supplied cable 3 Brief description With a junction box several load cells with max 350Ohm can be connected to one evaluation unit It is possible...

Page 4: ...4 CJ X467 CJ X468 BA e 2010 docx 5 Dimensions 5 1 CJ X467 1 Cable gland load cell 2 Mounting bracket 3 Screw 4 Seal Screw 5 Cable bushing Evaluation unit 6 Pressure relief valve 5 2 CJ X468 ...

Page 5: ...ox insert the cables for the measuring cells and the evaluation unit through the cable glands into the box and connect them to the circuit board Make sure that all wire connections are tight and the cables are not damaged EXC Supply EXC Supply SIG Signal SIG Signal SEN Probe SEN probe SHIE Screen Table 1 Connection of load cells and evaluation units only for connection to evaluation unit ...

Page 6: ...inal block If a 6 wire measuring cell is to be connected to a 4 wire connection block the sensor wires and the supply line must be connected together as shown in the following figure EXC and SEN as well as EXC and SEN 6 4 Grounding 7 Adjusting the balance Potis for corner adjustment ...

Page 7: ... for load cell 4 Repeat the setting for the other corners as needed until all corners have the same weight when the corner load is applied 8 Small troubleshooting 8 1 The scale seems to indicate an incorrect weight 1 Unload the scale and check if the scale returns to zero 2 Make sure that the object to be weighed is completely on the scale and is not supported elsewhere 8 2 The corners indicate un...