Quick start guide

Operating temperature, protection of the instruments and information about storage and the battery

1 Display

• 

Operating temperature*: KT220: from -40 to +70 °C; KH220, KTT220: from -20 to +70 °C

• 

KT220: IP65; KH220: IP20; KTT220: IP54*

• 

Storage temperature: from -40 to +85 °C

Battery power supply: 1x AA lithium 3.6 V battery

*With all the thermocouple probes connected.

2  Dimensions (mm)

KT220, KH220

KTT220

Reference

Parameters

KT 220

Temperature, humidity, current, voltage, electrical pulses, liquid pressure

KH 220

Temperature, humidity

 (internal sensor, an additional external humidity probe is available as an option),

 

current, voltage, electrical pulses, liquid pressure, light

KTT 220

Temperature

°C: 

Temperature in °Celsius.

°F: 

Temperature in °Fahrenheit

%HR:

 Relative humidity (KH 220)

DATASET is finished.
Indicates that one value is being recorded.
It flashes: the DATASET did not start already.
Flashing slowly: DATASET is between 80 and 90 % of the storage capacity.
Flashing quickly: DATASET is between 90 and 100 % of the storage capacity.
Constant: storage capacity full.

Constant: indicates that the batteries have to be replaced.

Indicates the channel number which is measuring.

Screen actualisation of measured values.

The displayed values are the maximum/minimum values recorded for the channels 
displayed.
Indication of the direction of exceeding the threshold in the recorded meas-
urement

REC

END

BAT

ACT

MIN

MAX

1 2
3 4

FULL

Summary of Contents for KH 220 Series

Page 1: ...CLASS 220 KISTOCK DATA LOGGERS Quick Start Guide www sauermanngroup com KT220 KH220 KTT220 EN FR ES ZH...

Page 2: ...an option current voltage electrical pulses liquid pressure light KTT 220 Temperature C Temperature in Celsius F Temperature in Fahrenheit HR Relative humidity KH 220 DATASET is finished Indicates tha...

Page 3: ...h button With Online option In this case your datasets are directly sent saved and displayed on your PC in real time Six types of dataset stop You can stop your dataset According to a date and time if...

Page 4: ...ontaining formalin that may be used for cleaning rooms or ducts Precautions for use please always use the de vice in accordance with its intended use and within parameters described in the technical f...

Page 5: ...pression de liquide lumi re KTT 220 Temp rature C Temp rature en degr s Celsius F Temp rature en degr s Fahrenheit RH Humidit relative KH 220 Indique que la campagne est termin e Enregistre les valeu...

Page 6: ...mpagnes de mesure sont directement enregistr es dans le PC et il est possible de visualiser les courbes d enregistrement en simultan sur votre cran Six conditions d arr t d enregistrement La campagne...

Page 7: ...l Pr cautions d utilisation veillez toujours utiliser l appareil conform ment l usage pr vu et dans les limites des param tres d crits dans les caract ristiques techniques afin de ne pas compro mettre...

Page 8: ...s el ctricos presi n de l quido luz KTT 220 Temperatura C Temperatura en grados Celsius F Temperatura en grados Farenheit RH Humedad relativa KH 220 Indica la finalizaci n de la campa a de registro Re...

Page 9: ...fecha y la hora lanzamiento con el programa lanzamiento por pulsaci n de bot n lanzamiento mediante el PC con la opci n Online En este caso los datos obtenidos son transferi dos grabados y mostrados d...

Page 10: ...ctos Precauciones de uso use siempre el dispositivo de acuerdo con su uso previsto y dentro de los par metros descritos en las caracter sticas t cni cas especificadas en este documento As no se compro...

Page 11: ...KT220 40 70 C KH220 KTT220 20 70 C KT220 IP65 KH220 IP20 KTT220 IP54 40 85 C 1 5 3 6 V KT220 KH220 KTT220 KT 220 KH 220 KTT 220 REC END BAT ACT MIN MAX 1 2 3 4 FULL 1 C F RH KH 220 80 90 90 100 2 mm...

Page 12: ...universal Conector micro USB Entradas para termopar 2 KT KH 220 KTT 220 Connecteur micro USB Entr e pour sonde universelle Connecteur micro USB 2 entr es thermocouples KTT 220 Micro USB connector Inp...

Page 13: ...mm KT 220 KH 220 KTT 220 5 6...

Page 14: ......

Page 15: ......

Page 16: ...Portail service clients Portal de servicio al cliente Use our Customer service portal to contact us Utilisez notre Portail service clients pour nous contacter Contacte con nosotros a trav s del Porta...

Reviews: