109
Adjusting the Position of the Media Sensor
When you use nonstandard media (for example, media with printing on the underside, or media with
a special shape), the media sensor cannot detect the I-mark or gap of the media correctly. In such
cases, make sure that the media sensor position is aligned with the I-mark or gap of the media.
The I-mark sensor of the product has a fixed position of 5 mm (0.2") measured from the product's
center frame.
The position of the Gap sensor is adjustable. You can adjust the Gap sensor position in the following
range.
S84NX: 5 to 66 mm (0.2" to 2.6") measured from the product's center frame.
S86NX: 5 to 81 mm (0.2" to 3.2") measured from the product's center frame.
1. Open the top cover.
2. Turn the media sensor adjustment knob (1) clockwise or counterclockwise to
adjust the Gap sensor position.
The green indicator (2) on top of the media sensor assembly shows the position of the Gap sensor.
Summary of Contents for S84NX
Page 1: ...FX3 LX...
Page 124: ...Checking the Ink Side of the Ribbon 124 The ink is coated on the inner side Face in ribbon...
Page 320: ...Operations in Continuous Mode 320 Timing Chart With Head Check...
Page 363: ...363 8 Press the button again to change to Online mode You can print to check the print quality...
Page 371: ...371 6 Hold the adjust collar 2 in the set position and tighten the screw 3...
Page 457: ...457 9 Rotate the bearing clamp 3 onto the bearing and attach it with the screw 2...
Page 465: ...465 8 Push the center of the pressure plate 3 to latch it in place...
Page 469: ...469 9 Rotate the bearing clamp 4 onto the bearing and attach it with the screw 3...
Page 553: ...553 Printer Languages SBPL Includes XML support SZPL SDPL SIPL...
Page 588: ...Back Cover October 2022 Version 1...