background image

31 

 

 

 

 

 

The blackbody’s temperature is set to 

40

 

and calibrated as default to- 

each  camera, 

NO

  further  settings  are  requiring  when  setting  up  the  system. 

Power on and install at the fix position as indicated! 

 

Summary of Contents for CK350-F

Page 1: ...and implement the most advanced security infrastructure in the world GDPR New EU regulation defines the handling of customer data On 28 May 2018 the new General Data Protection Regulation GDPR will become effective On one hand the new set of rules determines how companies must protect personal data and on the other hand how the free flow of data should be regulated GDPR supersedes the previous dat...

Page 2: ...1 SATIR CK350 F Fever Screening System User Manual SATIR 2020 all right reserved ...

Page 3: ...2 1 Camera Installation Guide In Door ...

Page 4: ... outdoor temperature not exceed 10 to 25 50 F to 77 F a shelter may not require for using the system But the camera must out of direct to any heat targets e g sun car power generator and avoid strong winds rain etc ...

Page 5: ...ent temperature should not exceed 0 to 30 32 F to 86 F 3 Keep the camera and optics out of direct sunlight wind rain or other sources of heat objects Changing the temperature of the camera and optics will have an adverse effect on measurement uncertainty A stable ambient environment will ensure the accuracy of the system ...

Page 6: ...5 Camera body Dimensions mm ...

Page 7: ...6 Wall Bracket Optional Dimensions mm ...

Page 8: ...7 Ceiling Bracket Optional Dimensions mm Camera Blackbody ...

Page 9: ...evice such as the voice box 2 ALARM IN2 Connects to the alarm device 8 DC12V 2A Power interface connects to the 12 V DC power adapter 110V to 240V power source 3 ALARM OUT2 9 Network interface Connects to the standard Ethernet cable CAT5 4 ALARM IN1 For individual system operation connect the power supply and network cable 5 ALARM OUT1 6 Audio Input Inputs the audio signal and receives the analog ...

Page 10: ... address to match the camera s IP address Camera default IP 192 168 0 121 I Click on Network and Internet and then on Network and sharing center II Click on Change adapter settings on the left side of the window III Right click on the relevant network adapter and click on properties IV In the networking tab select Internet Protocol Version 4 TCP IPv4 ...

Page 11: ...set up on Browser Internet Explorer Open IE browser enter IP address 192 168 0 121 IP Camera default Username admin Password admin Change the password only if needed not recommend change at first time Install Plugin ...

Page 12: ...11 2 3Configuration Make sure you can see the images go to the Configuration Human Thermometer Parameter Configure Turn on Face Detection Turn on Area Detection Clear Detection Area ...

Page 13: ...12 ...

Page 14: ...13 2 3 1 Draw a New Detection Area based on the installation environment Apply ...

Page 15: ...4 2 3 2 Alarm Temperature set up on IP camera Select Face Alarm Linkage set the Alarm Temperature Please make sure the alarm temperature is set to the same at Fever Screening Software Normal Temperature ...

Page 16: ...isible lens The angle of view should be similar to the thermal view Step 2 Select Mapping point Point One Point Two Point Three set three points in triangle position similar to above picture Step 3 Check the thermal view make sure the face recognition square is fully covering the whole face If not adjust three mapping point position ...

Page 17: ...16 ...

Page 18: ...4 Blackbody Calibration Select Thermal Calibration Enable Display Area Info Enable Draw a small square size smaller than the blackbody at the center of the Blackbody as a reference source for the camera Apply ...

Page 19: ...after the above settings DO NOT CHANGE ANY OTHER SETTINGS IF YOU ARE NOT SURE ABOUT THE FUNCTIONS ANY OTHER CHANGES MAY AFFECT THE CORRECT TEMPERATURE MEASUREMENT Please contact SATIR technical support team if you have any doubts ...

Page 20: ...er Screening Software on Windows 10 Computer Recommend Configurations Processor CPU Intel Core i5 sixth generation or newer or equivalent Memory 8 GB RAM Storage 500 GB SSD internal storage drive Or better computer for the best performance of the system ...

Page 21: ...e Setting 3 1 1 Log in to software default username admin default password admin the username and password is auto input at the first time of software installation Username and password can be change on the software ...

Page 22: ...21 3 1 2 Operation Interface First time login to the Interface please select Devices ...

Page 23: ...22 3 1 3 Add device Select Auto Search Start Search Select Model CK350 F Add Note Username and Password must be the same as the IP Camera on web browser ...

Page 24: ...23 3 1 4 Enter the Control Interface Back to Main Menu Select Face Recognition Enter the Face Recognition interface ...

Page 25: ...oftware Operation Select device CK350 F CH1 Visual Camera CK350 F CH2 Thermal Camera DOUBLE click Select enter the camera Screen can show both Visual and Thermal at the same time Recommend use Visual Camera only ...

Page 26: ...25 ...

Page 27: ... 3 1 7 Real time face recognition and temperature data When alarm target detected the square will turn to RED face temperature and info will be capture If the square is Blue it means the target is not in the measurement area ...

Page 28: ...27 Alarm temperature setting Go back to Main Menu Select Alarm Temperature ...

Page 29: ... default set to 36 0 to 37 3 we recommend the Alarm temperature set to 37 3 Anyone detect temperature over 37 3 a further Medical Mercury thermometer temperature check or quarantine action should be carrying out Note Alarm Temperature must set to the same as IP Camera ...

Page 30: ... not want to capture and store any face data on the systems On Face Recognition interface select setting bottom turn off the Visitor record function The software will not record any face data And there will be Audio alarms only If Audio alarm are not required please turn off the speaker ...

Page 31: ...30 5 Blackbody DON T TOUCH THE SURFACE WITH HAND OR SHARP OBJECT IR Target Surface Indicator Control Button Power Switch Power Socket ...

Page 32: ...31 The blackbody s temperature is set to 40 and calibrated as default to each camera NO further settings are requiring when setting up the system Power on and install at the fix position as indicated ...

Page 33: ... The temperature of the cavity is stable within 15 to 30 minutes after the device is powered on The target configuration is incorrect Check whether the emission rate and distance of the target are configured correctly An error occurs in accessing the web of the device after the upgrade The data in the cache of browser is not updated in time Delete the cache of the Internet Explorer The steps are a...

Page 34: ...htly with soft cloth Never use synthetic cleaners on the camera body or lens Never use thinners benzene synthetic cleaners or water to clean the camera These substances may distort or damage the equipment Blackbody Use a lens blower brush to remove dust and dirt If necessary gently wipe the blackbody with soft cloth or an eyeglass lens wiper to remove stubborn dirt NEVER rub or press forcefully on...

Page 35: ...Hot White Hot Rainbow Iron Red up to 17 modes Thermal Lens Characteristics Lens Type Fixed Focus Control Manual Focus Focal Length 8mm F F1 0 Field of View HFOV 46 VFOV 35 3 Visible Camera Image Sensor 1 1 9 Sony CMOS Effective Resolution 1920 H 1080 V Shutter Speed 1 50 1 64 000s Wide Dynamic Range True WDR 120dB Minimum Illumination Color 0 01Lux F1 2 AGC ON B W 0 001Lux F1 2 AGC ON S N Ratio Mo...

Page 36: ... Digital Zoom 16x Mirror Supported Defog Supported Motion Detection Supported Privacy Masking ON OFF 4 Areas Rectangle DVE Image Enhance Supported Audio Compression G 711 AMR RAW_PCM optional Smart Features Intelligent Functions Motion Detection Disk Alarm I O Alarm Temperature Alarm IVS Smart Body Detection Perimeter Virtual Fences Single Double Object Left Object Removed Smart Features Intellige...

Page 37: ...emperature difference DEV highest value average Network Ethernet RJ 45 10 100 Base T Protocols IPv4 IPv6 HTTP RTSP RTP RTCP TCP UDP DHCP DNS PPPOE SMTP SIP 802 1x Interoperability ONVIF CGI SDK Streaming Method Unicast Max User Access 10 Users Edge Storage NAS Local PC for instant recording MicroSD card up to 128GB Web Viewer IE11 Chrome Firefox Web Language English Chinese Czech French Hungarian ...

Page 38: ...DC12V POE IEEE 802 3af Power Consumption Max 10W Operating Temperature 30 C 60 C 22 F 140 F Storage Conditions 0 90 RH Certifications CE FCC Ingress Protection IP66 Casing Material Metal Dimensions 212 182 136mm Net Weight 2Kg ...

Page 39: ...38 ...