background image

®

 

VOICE MESSAGE GENERATOR  

VMG-16

 

vmg16_en 08/08 

The VMG-16 Voice Message Generator is designed for playback (reproduction) of 
prerecorded messages. It can work in conjunction with the CA-64 and INTEGRA series alarm 
control panels as an output expander, as well as with any other equipment capable of 
controlling the generator inputs. 

1.  Description of electronics board 

 

Fig. 1. Schematic view of VMG-16 voice message generator board. 

Legend: 

1 – package of DIP-switches – setting individual module address and module operating 

options (see: DIP-

SWITCHES

). 

2 – REC button – recording messages; 

3 – PLAY button – playing back recorded messages; 

4 – NEXT button – switching between successive messages; 

5 – microphone

6 – LED indicators (see: LED

 SIGNALING

): 

M0…M3 – message number; 

PLAY 

– message playback; 

REC 

– message recording; 

ME 

– message memory full; 

EA 

–  supply/communication with control panel. 

7 – LINE  socket  – connecting headset or external audio 

amplifier. 

Fig. 2. Set of LEDs on 

electronics board 

Summary of Contents for VMG-16

Page 1: ...ematic view of VMG 16 voice message generator board Legend 1 package of DIP switches setting individual module address and module operating options see DIP SWITCHES 2 REC button recording messages 3 P...

Page 2: ...t while the addressing order can be random It is recommended that you assign consecutive addresses starting from zero to expanders and modules to be connected to one bus Thus you can prevent any probl...

Page 3: ...ssages When in the OFF position it disables the message recording feature Fig 4 Example of setting the DIP switches for interaction with CA 64 or INTEGRA control panels 1 2 LED signaling The LED indic...

Page 4: ...e LINE socket as may be required 4 Connect the housing tamper contact cables to the TMP and COM terminals If no tamper contact is to be connected to the TMP input short circuit the TMP terminal to the...

Page 5: ...of any message with another one having a different length will make it necessary to re record all the subsequent messages 3 2 Playing back messages If the VMG 16 generator operates in conjunction with...

Page 6: ...level press the NEXT button to quit the volume level control function The LEDs showing the gain level will go off and the EA LED will go on Note If no operations are performed within 15 seconds of sta...

Page 7: ...declaration of conformity and product approval certificates are available for downloading on website www satel pl SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl...

Reviews: