MGD-300 

WIRELESS GLASS-BREAK DETECTOR 

mgd300_en 05/17 

 
The MGD-300 detector enables detection of a break of plate, tempered and laminated glass. 
The detector is supported by: 

  PERFECTA 16-WRL and PERFECTA 32-WRL control panels, 

  MICRA alarm module (firmware version 3.00 or newer), 

  VERSA-MCU controller (firmware version 1.02 or later), 

 MTX-300 

controller. 

This manual applies to the detector with electronics version 1.2 or later. 

1.  Features 

 Adjustable 

detection sensitivity. 

  Advanced two-path sound analysis. 

 LED 

indicator. 

  Battery status control. 

  Tamper protection against cover removal and tearing enclosure from the wall. 

2.  Description 

Alarms 

The detector reports alarm in the following cases: 

  glass break detection (registering a low frequency sound (impact) followed by a high 

frequency sound (glass break) in less than 4 seconds), 

  opening the tamper contact (tamper alarm). 

Test mode 

Placing a jumper across the TST pins as shown in Fig. 2 will activate the test mode. When 
the detector is running in the test mode, the LED indicator is enabled and the detector will 
report an alarm on registering a glass-break sound (high frequency sound). 

Periodic transmissions 

Every 15 minutes, the detector sends a transmission containing information on the status of 
the tamper contact and battery. Periodic transmissions are used to monitor presence and 
operation of the detector. 

Summary of Contents for MGD-300

Page 1: ...oval and tearing enclosure from the wall 2 Description Alarms The detector reports alarm in the following cases glass break detection registering a low frequency sound impact followed by a high frequency sound glass break in less than 4 seconds opening the tamper contact tamper alarm Test mode Placing a jumper across the TST pins as shown in Fig 2 will activate the test mode When the detector is r...

Page 2: ... contact is opened as well as in the test mode The LED indicates periodic transmission short flash 80 milliseconds test mode short flash every 3 seconds alarm ON for 2 seconds Battery status control When the battery voltage is below 2 6 V information about low battery is sent during each transmission 3 Selecting a mounting location The detector is designed for indoor installation The preferred loc...

Page 3: ...areful during installation and replacement of the battery The manufacturer is not liable for the consequences of incorrect installation of the battery The used batteries must not be discarded but should be disposed of in accordance with the existing rules for environment protection 1 Open the enclosure Fig 7 2 Using the potentiometer set the detection sensitivity 3 Set the jumper on the TST pins a...

Page 4: ...the test mode 12 Using wall plugs screw anchors and screws fasten the enclosure base to the mounting surface Fig 9 13 Close the enclosure 5 Specifications Operating frequency band 433 05 434 79 MHz Radio communication range in open area MICRA VERSA MCU MTX 300 up to 200 m PERFECTA up to 400 m Battery CR123A 3 V Battery life expectancy up to 3 years Standby current consumption 30 µA Maximum current...

Reviews: