SATEL INTEGRA
Plus
65
– the authorization method depends on the status of selected output (the output active –
code and card; the output inactive – code or card).
In case of the authorization using code and card, the executed function depends on
the second identifier.
The outputs 255 and 256 cannot be used for controlling the authorization method.
Alarms
– you can define which alarms will be triggered from the keypad:
– fire – pressing the key for approx. 3 seconds.
– panic – pressing the
key for approx. 3 seconds.
– auxiliary [medical] – pressing the
key for approx. 3 seconds.
– 3 wrong codes – entering invalid access codes three times.
Silent PANIC alarm
[Silent panic] – with this option enabled, pressing the
key for approx.
3 seconds will trigger the silent panic alarm.
Signaling entry delay
[Entry time s.] – with this option enabled, the keypad will audibly
signal the entry delay countdown.
Signaling exit delay
[Exit time sig.] – with this option enabled, the keypad will audibly signal
the exit delay countdown.
Signaling alarms
[Alarm signal.] – with this option enabled, the keypad will signal the alarms
audibly.
Key sounds
[Key sounds] – with this option enabled, pressing the keypad keys is confirmed
by beeps.
Signaling troubles in partially arm
[Trbl.in p.arm.] – with this option enabled, the keypad
signals troubles by means of the
LED, if some of the operated partitions are armed
(the troubles are not signaled if all partitions are armed).
Signal new trouble
[New trbl.sign.] – with this option enabled, the keypad can audibly signal
the occurrence of a new trouble (if the T
ROUBLE MEMORY UNTIL REVIEW
system option is
enabled).
Show code entering
[Show code ent.] – with this option enabled, entering the code is
presented on the keypad display by asterisks.
Show keypad name
[Name (2nd row)] – with this option enabled, the keypad name is
presented in the lower line of the display.
Exit delay clearing enable
[Fin.exit time] – with this option enabled, the exit delay time in
partitions with the E
XIT DELAY CLEARING
option enabled can be shortened after pressing in
turn the 9 keys.
Show violated zones
[Zone violation] – with this option enabled, violating the CHIME signal
triggering zone result additionally in the zone name being displayed.
Auto-Arm delay countdown
[Auto-arm delay] – with this option enabled, the auto-arm delay
countdown in partition is signaled acoustically.
Signal on wrong card
[Unkn.card sig.] – option available for the INT-KLCDR keypad. If
enabled, reading in an unknown card will be signaled by two long beeps.
Event after 3 readings
[Ev.3 unk.cards] – option available for the INT-KLCDR keypad. If
enabled, reading in an unknown card three times will save the event.
Alarm after 3 readings
[Al.3 unk.cards] – the option is available, if the E
VENT AFTER
3
READINGS
option is enabled. When enabled, reading in an unknown card three times will
trigger an alarm.
Display mode switching
[Dspl.mode chg.] – with the option enabled, you can toggle the
display between the standby mode and the partition status display mode by using the 9
key.