30 Programming
SATEL
Configuring the D
LOAD
X program
The following parameters required for establishing connection should be programmed in the
"Identifiers and tel. no" window:
the number of TCP port that will be used for communication (in most cases the port
number should be identical to that programmed in the ETHM-1 module, except where
communication is effected through a network device on which redirection to another port
occurs);
the key with which the data sent through the Ethernet will be encrypted (must be identical
to that programmed in the ETHM-1 module);
the network address of ETHM-1 module, if communication is to be initiated from the
D
LOAD
X program.
You can program a separate set of parameters for connections via the Wide Area
Network (WAN) and connections within the Local Area Network (LAN). Make your
choice using the "Connection" field. When selecting the LAN connection, you should at
the same time indicate the ETHM-1 module, whose settings (P
ORT
(D
LOAD
X)
and K
EY
(D
LOAD
X)) will be used for establishing communication.
Connection initialized from the
D
LOAD
X
program
Before initiating the connection, make sure that the suitable connection establishing
method is selected in the "Identifiers and tel. no" window, "Connection" field.
1. Click on the
button in the D
LOAD
X program.
2. A drop-down menu will be displayed. Select "TCP/IP: DloadX -> ETHM" in it.
3. A window will open. Click on the "Connection" button in the window.
4. The D
LOAD
X program will inform you about establishing connection by means of
a suitable message.
Connection initialized by the control panel
1. Click on the
button in the D
LOAD
X program.
2. A drop-down menu will be displayed. Select "TCP/IP: DloadX -> ETHM" in it.
3. In the LCD keypad connected to the control panel, start the ETHM-1
–
D
LOAD
X function
([
code
]
D
OWNLOADING
ETHM-1
–
D
LOAD
X). The function is available to the installer,
administrator and the user having the D
OWNLOADING STARTING
right.
4. The D
LOAD
X program will inform you about establishing connection by means of
a suitable message.
2.2.8 Starting remote GPRS programming
The GPRS programming is possible when the GSM module with LEON industrial type
telephone is connected to the control panel as an external modem:
– GSM LT-1 with firmware version 1.14 (or newer);
– GSM LT-2 with firmware version 2.14 (or newer);
– GSM-4 with firmware version 4.14 (or newer);
– GSM-5 with firmware version 5.14 (or newer).
Configuring the control panel
The following options should be enabled in the control panel:
E
XTERNAL MODEM
;