background image

®

 

VOICE MESSAGE GENERATOR 

INT-VMG

 

int-vmg_en 05/15 

The INT-VMG module allows loud playback of pre-recorded messages when certain events 
occur. It can be used in conjunction with the INTEGRA control panels (as output expander), 
and with any devices that are able to control the generator inputs. This manual applies to the 
module with electronics version 2.1 and firmware version 1.00 (or later). 

1.  Features 

  Ability to record up to 32 messages. 

  Over 17 minutes for messages. 

  Managing voice messages by means of the free VMG-SOFT program. 

  Ability to record messages using the built-in microphone. 

  Control via the communication bus (INTEGRA control panels) or 16 inputs. 

  Built-in amplifier allowing direct connection of a loudspeaker. 

  Mini-jack for headphones or external audio amplifier. 

  Volume control for playback of messages. 

  Additional NC type tamper input. 

2.  Specifications 

Supply voltage ................................................................................................... 12 V DC ±15% 
Standby current consumption ..........................................................................................75 mA 
Maximum current consumption......................................................................................500 mA 
Recommended impedance of loudspeaker connected to SPEAKER terminals................... 8 

 

Maximum power of speaker output......................................................................................6 W 
Environmental class according to EN50130-5 ......................................................................... II 
Operating temperature range..................................................................................-10...+55 °C 
Maximum humidity..........................................................................................................93±3% 
Dimensions of electronics board........................................................................... 68 x 140 mm 
Weight................................................................................................................................. 80 g 
 

The declaration of conformity may be consulted at www.satel.eu/ce 

3.  Functional description 

The INT-VMG module connected to the control panel communication bus is recognized as an 
output expander. Activation of an output assigned to the module results in the message 
playback (the first output – message 0, the second output – message 1, etc.). The situation in 
which a message is played back depends on how the output has been preprogrammed. 
The message will also be played back after shorting the selected module input to ground. 
This allows you to use any device for control. According to the factory settings, the inputs 
trigger messages from 0 to 15 (the input 1 triggers the message 0, input 2 – message 1, 
etc.). Messages having other numbers can be assigned to the inputs. 
The module can queue up to 96 message playback commands. 

Summary of Contents for INT-VMG

Page 1: ...A Maximum current consumption 500 mA Recommended impedance of loudspeaker connected to SPEAKER terminals 8 Ω Maximum power of speaker output 6 W Environmental class according to EN50130 5 II Operating temperature range 10 55 C Maximum humidity 93 3 Dimensions of electronics board 68 x 140 mm Weight 80 g The declaration of conformity may be consulted at www satel eu ce 3 Functional description The ...

Page 2: ... is assigned to each LED LED is ON see Table 1 LED is OFF 0 The sum of these numerical values corresponds to the message number The messages are numbered from 0 to 31 LED M4 M3 M2 M1 M0 Number 16 8 4 2 1 Table 1 Numbers assigned to the LEDs which are lit ON mini jack socket for connecting a headset or an external audio amplifier connector for future applications connector used in the production pr...

Page 3: ...in the module if it is connected to the control panel communication bus A number is assigned to each DIP switch in the ON position see Table 2 in the OFF position 0 The sum of these numbers corresponds to the set address These switches allow you to set an address within the range from 0 to 31 DIP switch number 1 2 3 4 5 Number 1 2 4 8 16 Table 2 Numbers assigned to DIP switches in ON position The ...

Page 4: ...able length should not exceed 1000 m If it exceeds 300 meters it may be necessary to use several wires connected in parallel for each signal 4 Depending on your needs connect the loudspeaker to SPEAKER terminals audio amplifier or headset to LINE socket 5 Connect the tamper contact wires of module enclosure to the TMP and COM terminals If the module is not to monitor the tamper contact status the ...

Page 5: ...SATEL INT VMG 5 ...

Page 6: ... down the PLAY button for about 2 seconds The LEDs shown in Figure 3 will blink three times and then will present the currently set volume the more LEDs light up the higher the volume all LEDs are lit the maximum volume no LED is lit the minimum volume 2 Press the NEXT button repeatedly until the desired volume is set 3 Press the PLAY button to exit the volume control function The function will en...

Page 7: ... Windows system will automatically detect the connection of a new device and will launch the wizard that will guide you through the procedure of installation of drivers for your new hardware The drivers can be downloaded from www satel eu Some versions of the Windows operating system may give you a warning that the driver has not passed the compatibility test Despite these warnings installation of...

Page 8: ...SATEL sp z o o ul Budowlanych 66 80 298 Gdańsk POLAND tel 48 58 320 94 00 www satel eu ...

Reviews: