8. Connect the supply wires to the KPD and COM terminals. The keypad can be powered
directly from the control panel, from expander with power supply or from a power supply
unit.
9. Place the front panel onto the catches, snap close the enclosure.
3.1 Description of terminals
KPD
- power supply input.
COM
-
common
ground.
DTM
-
data.
CKM
-
clock.
A RS485 B
- unused terminals.
Z1, Z2
-
zones.
4. Addressing
Each keypad connected to the control panel must have its individual address set on it. By
default, address 0 is set in the keypad.
When started, only the control panel with factory default settings can provide support
for all keypads connected to the bus, irrespective of the addresses set in them. In all
other cases, the control panel will block operation of the keypads having identical
addresses.
4.1 Keypad connected to INTEGRA / INTEGRA Plus control panel
The keypad must have an address set in it:
from the 0 to 3 range, if it is connected to the INTEGRA 24 or INTEGRA 32 control panel;
from 0 to 7 range, if it is connected to another INTEGRA or INTEGRA Plus control panel.
The address set in the keypad determines the numbers to be given to the keypad zones (see
the I
NSTALLER MANUAL
for INTEGRA or INTEGRA Plus control panels).
4.1.1 Programming keypad address by means of service function
1. Tap
on the main screen. The “Advanced” screen will be displayed.
2. Tap
. The terminal will be displayed.
3. Enter the
service code
(by default: 12345) and tap
. The user menu will be
displayed.
4. Tap
. The service mode will start up.
5. Start the K
EYPADS ADDR
. function (
S
TRUCTURE
H
ARDWARE
I
DENTIFICATION
K
EYPADS
ADDR
.). The “This LCD address (n, 0-x)” message will appear on the displays of all
keypads connected to the control panel (n – keypad address; 0-x – range of supported
addresses).
6. Tap the key with the digit corresponding to the address which is to be programmed on the
keypad.
7. To terminate the address change function, tap
. The function will be terminated
automatically after 2 minutes from being started. Termination of the function will restart