Page 1: ...ASP 215 Wireless indoor siren Firmware version 1 00 asp 215_en 01 19 SATEL sp z o o ul Budowlanych 66 80 298 Gdańsk POLAND tel 48 58 320 94 00 www satel eu ...

Page 2: ...y improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Please visit us at http www satel eu Hereby SATEL sp z o o declares that the radio equipment type ASP 215 is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is av...

Page 3: ...tandard for the ABAX 2 system Transmission channel diversity 4 channels for automatic selection of the one that will enable transmission without interference with other signals in the 868 MHz frequency band ABAX 2 system only Remote update of siren firmware ABAX 2 system only Remote configuration Built in temperature sensor temperature measurement range from 10 C to 55 C Power supply from 3 V lith...

Page 4: ...50131 4 EN 50131 5 3 Security grade according to EN 50131 1 Grade 2 Environmental class according to EN50130 5 II Operating temperature range 10 C 55 C Maximum humidity 93 3 Dimensions 87 x 133 x 37 mm Weight 180 g 3 Description enclosure base piezoelectric transducer tamper switch battery cover locking screws enclosure cover ...

Page 5: ...und with falling frequency from 2000 Hz to 1450 Hz within 1 second Table 1 Tone types for acoustic signaling Blocking the tamper signaling Opening the tamper switch will not trigger the alarm in the following cases for 40 seconds after the battery is installed when the ABAX 2 ABAX system is running in the test mode the way of starting ending the test mode is described in the ABAX 2 ABAX controller...

Page 6: ...nment protection The siren should be installed indoors in spaces with normal air humidity The siren must be installed on the wall high above the floor at a hard to access location so as to minimize the risk of tampering Make sure that some free space is left above the siren at least 1 cm Otherwise it will be impossible to replace the cover 1 Remove the cover locking screws 2 Lift up the enclosure ...

Page 7: ...place of future installation without having to put the siren there 8 Remove the siren cover 9 Remove the battery 10 Place the enclosure base on the wall and mark the location of mounting holes Fig 2 Remember to take into account the mounting hole for tamper protection 11 Drill the holes for wall plugs anchors 12 Use wall plugs anchors and screws to secure the enclosure base to the mounting surface...