11. Fasten the electronics module in the enclosure.
12. If you have mounted the detector on a bracket, connect an additional tamper switch to the
TMP terminals (black wire to one terminal, blue wire to the other) and remove the jumper
from the pins.
13. Replace the cover.
14. Configure the detector settings (sensitivity of PIR sensor, sensitivity of microwave sensor,
sensitivity of dusk sensor [detection threshold], etc. – see the ABAX 2 / ABAX controller
manual / the INTEGRA 128-WRL control panel manual).
If the detector is to be pet immune, for the infrared and microwave sensors do not set
the detection sensitivity higher than default (PIR sensor sensitivity: 2, MW sensor
sensitivity: 1).
15. Start the test mode (see the ABAX 2 / ABAX controller manual / the INTEGRA 128-WRL
control panel manual).
16. Check whether moving around within the detector coverage area will get the LEDs to
come on. Fig. 9 shows the maximum detection range and the creep zone .
17. End the test mode.
4.1 Angle bracket mounting
1. Attach extra tamper switch:
– screw the holder to the tamper switch (Fig. 7-I),
– screw the tamper unit to the enclosure base (Fig. 7-III).
Figure 7 shows mounting the tamper switch in one of two available positions. The
place of tamper switch installing depends on the way of angle bracket mounting. If the
tamper switch is to be installed in the other position, place tamper switch holder on the
other side.
2. Prepare openings in the bracket for screws.
3. Using wall plugs and screws, fasten the bracket to the wall.
4. Run the tamper switch wires through the hole made in the enclosure base.
It is recommended that the tamper switch wires be placed in a heat shrink tubing. This
will reduce the risk of water penetration into the enclosure.
5. Using screws, fasten the enclosure base to the bracket (Fig. 7-IV).