Additionally, the ACX-201 expander module sends information about:
status of AUX1 and AUX2 power supply outputs – information on overload is sent when
the AUX1 or AUX2 output load exceeds 0.5 A.
battery status – information on low battery is sent when the battery voltage drops below
11 V for more than 12 minutes (3 battery tests). The expander will kept sending this
information to the controller until the battery voltage rises and remains above 11 V for
longer than 12 minutes (3 battery tests).
AC power status – information on the loss of power supply is sent when the AC power loss
lasts for more than 30 seconds. The AC power restore is reported with the same delay.
9.4 230 V AC wireless controllers
Activation of the output to which the controller is assigned will result in energizing the
230 V AC electrical circuit (if reverse polarity of the output has been programmed, the circuit
will be deenergized).
Depending on the operating mode, information on the button status (mode 0) or on the
electric circuit status (mode 1 and mode 2) is sent to the zone to which the controller is
assigned. Information on the button status is sent in real time. Information on the electric
circuit status is sent during the response time. Pressing the button / closing the electric circuit
means violation of the zone to which the controller is assigned.
10. APT-100 keyfobs
The maximum number of supported keyfobs depends on the maximum number of the control
panel users.
The data related to keyfobs are stored in the controller. After the controller containing
keyfob data is connected to the control panel, keyfobs will be automatically assigned
to the existing users.
10.1 Keyfobs in the INTEGRA / INTEGRA Plus system
The user can have one APT-100 keyfob. If more than one ABAX wireless system controllers
are connected to the INTEGRA / INTEGRA Plus control panels, the keyfob will be supported
by all of them. The keyfob data are automatically saved to all controllers.
When connecting the controller to the INTEGRA 128-WRL control panel or to the control
panel to which the ABAX system controller is already connected, you should make uniform
the data relating to APT-100 keyfobs. In the keypad service mode, the C
OPY
ABAX
KFOBS
function is available (
S
TRUCTURE
H
ARDWARE
E
XPANDERS
C
OPY
ABAX
KFOBS
), which
enables copying of the keyfob data. In the D
LOAD
X program, to write the APT-100 keyfobs
data to a new controller, open the "Keyfobs ABAX" window and do the following:
INTEGRA 128-WRL – click on the "Write to all" button (the button is available, when the
ABAX system controller is connected to the control panel).
other INTEGRA / INTEGRA Plus control panels – click on the "Read" button and
immediately after reading the data, click on the "Write" button (after the data are read, you
must not make any changes).
The functions are executed by means of controlling the status of system zones. Using the
keyfob, you can control up to 6 zones in the alarm system. These zones should not exist
physically and the wiring type programmed in them must be different from N
O DETECTOR
and
F
OLLOW OUTPUT
. You can program any function for these zones. Pressing the keyfob button