Summary of Contents for ABAX 2

Page 1: ...ACD 220 Wireless curtain detector EN Firmware version 1 00 acd 220_en 10 21 SATEL sp z o o ul Budowlanych 66 80 298 Gdańsk POLAND tel 48 58 320 94 00 www satel eu ...

Page 2: ...device was placed on the market after 13 August 2005 The device meets the technical regulations of the Eurasian Customs Union SATEL aims to continually improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Please visit us at https support satel eu Hereby SATEL...

Page 3: ... communication 2 Alarms 2 Operating modes 2 Energy saving mode ECO 3 Test mode 3 LED 3 Supervision of motion detection system 3 Battery status control 3 3 Electronics board 3 4 Selecting a mounting location 4 5 Installation 4 6 Specifications 6 ...

Page 4: ...her signals in the 868 MHz 915 MHz frequency band Remote update of detector firmware Remote configuration Built in temperature sensor temperature measurement range from 10 C to 55 C LED indicator Supervision of motion detection system ECO option for longer battery life Battery status control Tamper protection against enclosure opening and removal from mounting surface 2 Description Radio communica...

Page 5: ...e battery is inserted to indicate warm up of the detector The LED also works in the test mode in which it indicates periodical communication short flash 80 milliseconds alarm ON for 2 seconds Supervision of motion detection system When the motion detection system starts malfunctioning the detector will report an alarm during periodical communication The alarm will keep going until the fault is cle...

Page 6: ...ded by the manufacturer or handling the battery improperly Do not crush the battery cut it or expose it to high temperatures throw it into the fire put it in the oven etc Do not expose the battery to very low pressure due to the risk of battery explosion or leakage of flammable liquid or gas Be particularly careful during installation and replacement of the battery The manufacturer is not liable f...

Page 7: ...r than 40 select another mounting location Sometimes it is sufficient to shift the device ten or twenty centimeters You can use the ARF 200 tester to test the radio signal strength at the future mounting location without having the detector physically there 6 Remove the detector cover Fig 3 7 Use wall plugs anchors and screws to mount the enclosure base to the surface Fig 4 The wall plugs delivere...

Page 8: ... to 2 years Temperature measurement range 10 C 55 C Temperature measurement accuracy 1 C Standby current consumption 70 µA Maximum current consumption 15 mA Detectable speed 0 3 1 m s Warm up period 5 s Coverage area 5 m x 1 m 15 Complied with standards EN 50130 4 EN 50130 5 Environmental class according to EN 50130 5 II Operating temperature range 10 C 55 C Maximum humidity 93 3 Dimensions 20 x 1...