7.  Configure  the  detector  settings  (sensitivity  of  dusk  sensor  [detection  threshold], 

temperature  threshold  parameters  [threshold  type:  high  /  low,  temperature  value  and 
tolerance], etc. 

– see ABAX 2 controller manual). 

8.  Start the test mode (see ABAX 2 controller manual). 
9.  Check whether the dusk sensor works properly. When tested, the entire detector must be 

covered, e.g. by a cardboard box or a thick and dark piece of fabric. 

10. End the test mode. 

 

4  Specifications 

Operating frequency band................................................................... 868.0 MHz 

÷ 868.6 MHz 

Radio communication range (in open area) 

ACU-220 .............................................................................................. up to 2000 m 
ACU-280 .............................................................................................. up to 1600 m 

Battery.................................................................................................................... CR123A 3 V 
Battery life expectancy .......................................................................................... up to 2 years 
Light intensity measurement range .......................................................................... 2 lx...250 lx 
Temperature measurement range ....................................................................... -

30°C...+70°C 

Temperature measurement accuracy ................................................................................ 

±1°C 

Standby current consumption .......................................................................................... 20 

µA 

Maximum current consumption ........................................................................................ 12 mA 
Warm-up period .................................................................................................................... 5 s 
Environmental class according to EN 50130-5 ....................................................................... III 
Operating temperature range ............................................................................... -30

°C...+70°C 

Maximum humidity .......................................................................................................... 93

±

3% 

IP code ................................................................................................................................IP65 
Dimensions ................................................................................................... 58 x 115 x 34 mm 
Weight ................................................................................................................................. 95 g 
 

Summary of Contents for abax 2 ADD-200

Page 1: ...ADD 200 Wireless outdoor dusk and temperature detector Firmware version 1 00 add 200_en 09 20 SATEL sp z o o ul Budowlanych 66 80 298 Gdańsk POLAND tel 48 58 320 94 00 www satel eu ...

Page 2: ...improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Please visit us at https support satel eu Hereby SATEL sp z o o declares that the radio equipment type ADD 200 is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is...

Page 3: ... 1 Features 2 2 Description 2 Radio communication 2 Dusk sensor 2 Temperature sensor 3 Energy saving mode ECO 4 Test mode 4 LED 4 Battery status control 4 Electronics board 4 3 Installation 4 4 Specifications 6 ...

Page 4: ...mote configuration LED indicator ECO option for longer battery life Battery status control Weatherproof enclosure of high mechanical strength 2 Description Radio communication The detector connects to the controller at regular time intervals to provide information about its state periodical communication Additional communication will take place when light intensity drops below the threshold rises ...

Page 5: ... lx 125 lx 15 150 lx 188 lx 16 200 lx 250 lx Table 1 Temperature sensor You can program one of two temperature detection thresholds low L or high H The detector will alert of the threshold being exceeded if the temperature drops below the programmed value in the case of the low L threshold rises above the programmed value in the case of the high H threshold Information about the current temperatur...

Page 6: ...ng the battery to indicate the warm up of the detector When in test mode the LED indicates periodical communication short flash 80 milliseconds Battery status control When the battery voltage is below 2 75 V information about low battery is sent during each transmission Electronics board Do not remove the electronics board from the enclosure to avoid damage to the components on the board Figure 2 ...

Page 7: ...nd configure the ADD 200 detector using the DLOADX program 2 Press the gasket included with the detector into the groove of the enclosure cover The gasket must fill the entire groove so that both of the gasket ends touch each other Fig 3 Do not shorten the gasket it is fitted to the length of the groove It is recommended that the ends of the gasket are situated on the bottom of the enclosure after...

Page 8: ... piece of fabric 10 End the test mode 4 Specifications Operating frequency band 868 0 MHz 868 6 MHz Radio communication range in open area ACU 220 up to 2000 m ACU 280 up to 1600 m Battery CR123A 3 V Battery life expectancy up to 2 years Light intensity measurement range 2 lx 250 lx Temperature measurement range 30 C 70 C Temperature measurement accuracy 1 C Standby current consumption 20 µA Maxim...

Reviews: